12 DATA USED FOR POSITIONING CONTROL
12.2 List of Buffer Memory Addresses
361
12
20
(14H)
170
(AAH)
320
(140H)
470
(1D6H)
[Pr.13] Software stroke limit lower limit value
-2147483648
Detailed parameter
1
21
(15H)
171
(ABH)
321
(141H)
471
(1D7H)
22
(16H)
172
(ACH)
322
(142H)
472
(1D8H)
[Pr.14] Software stroke limit selection
0
23
(17H)
173
(ADH)
323
(143H)
473
(1D9H)
[Pr.15] Software stroke limit valid/invalid setting
0
24
(18H)
174
(AEH)
324
(144H)
474
(1DAH)
[Pr.16] Command in-position width
100
25
(19H)
175
(AFH)
325
(145H)
475
(1DBH)
26
(1AH)
176
(B0H)
326
(146H)
476
(1DCH)
[Pr.17] Torque limit setting value
300
27
(1BH)
177
(B1H)
327
(147H)
477
(1DDH)
[Pr.18] M code ON signal output timing
0
28
(1CH)
178
(B2H)
328
(148H)
478
(1DEH)
[Pr.19] Speed switching mode
0
29
(1DH)
179
(B3H)
329
(149H)
479
(1DFH)
[Pr.20] Interpolation speed specification method
0
30
(1EH)
180
(B4H)
330
(14AH)
480
(1E0H)
[Pr.21] Current feed value during speed control
0
31
(1FH)
181
(B5H)
331
(14BH)
481
(1E1H)
[Pr.22] Input signal logic selection
0
32
(20H)
182
(B6H)
332
(14CH)
482
(1E2H)
[Pr.23] Output signal logic selection
0
33
(21H)
[Pr.24] Manual pulse generator input selection
0
34
(22H)
184
(B8H)
334
(14EH)
484
(1E4H)
[Pr.150] Speed-position function selection
0
35
(23H)
185
(B9H)
335
(14FH)
485
(1E5H)
System area
36
(24H)
186
(BAH)
336
(150H)
486
(1E6H)
[Pr.25] Acceleration time 1
1000
Detailed parameter
2
37
(25H)
187
(BBH)
337
(151H)
487
(1E7H)
38
(26H)
188
(BCH)
338
(152H)
488
(1E8H)
[Pr.26] Acceleration time 2
1000
39
(27H)
189
(BDH)
339
(153H)
489
(1E9H)
40
(28H)
190
(BEH)
340
(154H)
490
(1EAH)
[Pr.27] Acceleration time 3
1000
41
(29H)
191
(BFH)
341
(155H)
491
(1EBH)
42
(2AH)
192
(C0H)
342
(156H)
492
(1ECH)
[Pr.28] Deceleration time 1
1000
43
(2BH)
193
(C1H)
343
(157H)
493
(1EDH)
44
(2CH)
194
(C2H)
344
(158H)
494
(1EEH)
[Pr.29] Deceleration time 2
1000
45
(2DH)
195
(C3H)
345
(159H)
495
(1EFH)
46
(2EH)
196
(C4H)
346
(15AH)
496
(1F0H)
[Pr.30] Deceleration time 3
1000
47
(2FH)
197
(C5H)
347
(15BH)
497
(1F1H)
Address
Decimal (Hexadecimal)
Name
Default
value
Auto
refresh
Memory area
Axis 1
Axis 2
Axis 3
Axis 4
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......