12 DATA USED FOR POSITIONING CONTROL
12.2 List of Buffer Memory Addresses
379
12
Synchronized refresh-dedicated area
55009 (D6E1H)
Interrupt setting
No.10
[Md.65] Interrupt factor detection flag
0
Interrupt setting
data
55073 (D721H)
[Cd.50] Interrupt factor mask
0
55137 (D761H)
[Cd.51] Interrupt factor reset request
0
55201 (D7A1H)
[Pr.900] Interrupt factor setting
0
55265 (D7E1H)
[Pr.901] Axis No. for interrupt factor
0
55010 (D6E2H)
Interrupt setting
No.11
[Md.65] Interrupt factor detection flag
0
55074 (D722H)
[Cd.50] Interrupt factor mask
0
55138 (D762H)
[Cd.51] Interrupt factor reset request
0
55202 (D7A2H)
[Pr.900] Interrupt factor setting
0
55266 (D7E2H)
[Pr.901] Axis No. for interrupt factor
0
55011 (D6E3H)
Interrupt setting
No.12
[Md.65] Interrupt factor detection flag
0
55075 (D723H)
[Cd.50] Interrupt factor mask
0
55139 (D763H)
[Cd.51] Interrupt factor reset request
0
55203 (D7A3H)
[Pr.900] Interrupt factor setting
0
55267 (D7E3H)
[Pr.901] Axis No. for interrupt factor
0
55012 (D6E4H)
Interrupt setting
No.13
[Md.65] Interrupt factor detection flag
0
55076 (D724H)
[Cd.50] Interrupt factor mask
0
55140 (D764H)
[Cd.51] Interrupt factor reset request
0
55204 (D7A4H)
[Pr.900] Interrupt factor setting
0
55268 (D7E4H)
[Pr.901] Axis No. for interrupt factor
0
55013 (D6E5H)
Interrupt setting
No.14
[Md.65] Interrupt factor detection flag
0
55077 (D725H)
[Cd.50] Interrupt factor mask
0
55141 (D765H)
[Cd.51] Interrupt factor reset request
0
55205 (D7A5H)
[Pr.900] Interrupt factor setting
0
55269 (D7E5H)
[Pr.901] Axis No. for interrupt factor
0
55014 (D6E6H)
Interrupt setting
No.15
[Md.65] Interrupt factor detection flag
0
55078 (D726H)
[Cd.50] Interrupt factor mask
0
55142 (D766H)
[Cd.51] Interrupt factor reset request
0
55206 (D7A6H)
[Pr.900] Interrupt factor setting
0
55270 (D7E6H)
[Pr.901] Axis No. for interrupt factor
0
55015 (D6E7H)
Interrupt setting
No.16
[Md.65] Interrupt factor detection flag
0
55079 (D727H)
[Cd.50] Interrupt factor mask
0
55143 (D767H)
[Cd.51] Interrupt factor reset request
0
55207 (D7A7H)
[Pr.900] Interrupt factor setting
0
55271 (D7E7H)
[Pr.901] Axis No. for interrupt factor
0
Address
Decimal (Hexadecimal)
Name
Default
value
Auto
refresh
Memory area
Axis 1
Axis 2
Axis 3
Axis 4
54000
(D2F0H)
54001
(D2F1H)
54002
(D2F2H)
54003
(D2F3H)
[Md.61] Analysis complete flag
0
Synchronized
refresh-dedicated
area
Address
Decimal (Hexadecimal)
Name
Default
value
Auto
refresh
Memory area
Common for Axis 1 to 4
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......