8 COMMON FUNCTIONS
8.7 Amplifier-less Operation Function
313
8
Restrictions
• In the amplifier-less operation mode, the following monitor data operations differ from those in the normal operation mode.
• If the module is powered on or the CPU module is reset in the amplifier-less operation mode, the operation mode is
switched to the normal operation mode.
• Acquisition timing of external input signals and start timing differ between the amplifier-less operation mode and the normal
operation mode. Check the actual operation with the actual equipment.
• The amplifier-less operation function cannot be used in the test mode. If the amplifier-less operation mode is requested in
the test mode, Error at switching from normal operation mode to amplifier-less operation mode (Error code: 18B0H) occurs
and the operation mode is not switched.
Setting method
The following table lists the data used with the amplifier-less operation function.
■
System control data
■
System monitor data
Monitor item
Monitor details
Buffer memory address
Axis 1 Axis 2 Axis 3 Axis 4
[Md.30]
External I/O
signal
The ON or OFF state of External I/O signal is stored.
816
916
1016
1116
b0
Lower limit signal
The ON or OFF state set in
[Cd.44] External input signal
operation device is reflected
on these signals.
b1
Upper limit signal
b2
Drive unit READY signal
b3
Stop signal
b4
External command signal
b5
Zero signal
b6
Near-point dog signal
b7
Use prohibited
b8
Deviation counter clear signal
These signals turn on or off in
the same way in the normal
operation mode.
b9 to b15
Use prohibited
Setting item
Setting
value
Setting details
Initial value
at the
factory
Buffer memory address
Axis 1 Axis 2 Axis 3 Axis 4
[Cd.137]
Amplifier-less
operation
mode
switching
request
Switches the operation mode.
ABCDH: Switches the operation mode from the normal
operation mode to the amplifier-less operation mode.
0000H: Switches the operation mode from the amplifier-
less operation mode to the normal operation mode.
0000H
1926
[Cd.44]
External input
signal
operation
device
Set the external input signal status for the amplifier-less
operation mode. (Acquisition cycle: 0.88ms)
0000H
1928
1929
1930
1931
b0
Lower limit signal
0: OFF
1: ON
b1
Upper limit signal
b2
Drive unit READY signal
b3
Stop signal
b4
External command signal
b5
Zero signal
b6
Near-point dog signal
b7 to b15
Use prohibited
Set 0.
Monitor item
Monitored
value
Monitor details
Buffer memory address
Axis 1 Axis 2 Axis 3 Axis 4
[Md.70]
Amplifier-less
operation mode
status
Indicates the current operation mode.
0: In normal operation mode
1: In amplifier-less operation mode
1201
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......