56
2 OPR CONTROL
2.2 Machine OPR
Data setting method
Data setting method is used to set a point at which the workpiece is positioned by a manual feed such as JOG operation as an
OP.
When the machine OPR is performed using the data setting method, Deviation counter clear signal is output to the drive unit
and the current feed value and machine feed value are overwritten with the OP address.
Operation chart
Operation precautions
• The OPR parameter areas ([Pr.43] to [Pr.57]) other than [Pr.45] OP address and [Pr.55] Deviation counter clear signal
output time are not used for the data setting method. However, if a set value is outside the setting range and PLC READY
signal [Y0] is turned on, an error occurs and RD75 READY signal [X0] does not turn on. To avoid the occurrence of an error
when PLC READY signal [Y0] is turned on, Set values within the setting range (or initial values) for the unused OPR
parameter areas.
• When performing an OPR operation using Data setting method for a device for which the backlash compensation function
is used, perform the manual control beforehand. Otherwise the backlash compensation cannot be properly executed.
t
ON
ON
ON
OFF
OFF
OFF
v
Pr.55
Md.26
Md.31
Md.31
Md.20
Md.21
Machine OPR start
(Positioning start signal)
[Y10, Y11, Y12, Y13]
OPR request flag
[ Status: b3]
OPR complete flag
[ Status: b4]
Deviation counter clear output
Axis operation status
Current feed value
Machine feed value
Deviation counter clear signal
output time
OPR
Standby
Standby
Inconsistent
A value of the movement amount is stored.
OP address
Manual feed such
as JOG operation
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......