12 DATA USED FOR POSITIONING CONTROL
12.7 Monitor Data
443
12
12.7
Monitor Data
System monitor data
[Md.1] In test mode flag
This area stores whether the test mode is used in the engineering tool or not.
■
Buffer memory address
The following table shows the buffer memory address of this area.
[Md.3] Start information
This area stores the start information (restart flag, start origin, and starting axis).
• Restart flag: Indicates whether the operation has been temporarily stopped and restarted or not.
• Start origin: Indicates the source of the start signal.
• Starting axis: Indicates the started axis.
The following figure shows the information to be stored.
■
Buffer memory address
For the buffer memory address of this area, refer to the following.
In test mode flag
Stored value
Not in test mode
0
In test mode
1
Buffer memory name
Common for Axis 1 to 4
[Md.1] In test mode flag
1200
0 0 0 0 0
b15
b12
b8
b4
b0
00
01
10
0
1
3
1
2
4
Not used
Monitor
value
CPU module
Stored contents
Stored value
External signal
Engineering tool
Start origin
Stored contents
Stored value
Restart flag
Axis 1
Axis 2
Axis 3
Axis 4
Stored contents
Stored value
Buffer
memory
Restart flag OFF
Restart flag ON
Starting axis
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......