12 DATA USED FOR POSITIONING CONTROL
12.8 Control Data
[Cd.34] Step mode
Set the units by which a step operation is carried out.
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Default value
The default value is 0: Carry out step operation in deceleration units for all the axes.
[Cd.35] Step valid flag
Set whether to validate step operations.
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Default value
The default value is 0: Do not carry out step operation for all the axes.
[Cd.36] Step start request
When the step function is used, set this area to continue the operation stooped by the step operation.
• The step operation continues by setting 1: Continue step operation for this area of the axis where step operation is stopped
correctly.
• After the step start request is accepted, 0 is automatically stored. Storing 0 indicates the completion of the step start
request acceptance.
■
Buffer memory address
The following table shows the buffer memory address of this area.
■
Default value
The default value is 0 for all the axes.
Step mode
Setting value
Carry out step operation in deceleration units
0
Carry out step operation in data No. units
1
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Cd.34] Step mode
1544
1644
1744
1844
Step valid flag
Setting value
Do not carry out step operation
0
Carry out step operation
1
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Cd.35] Step valid flag
1545
1645
1745
1845
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Cd.36] Step start request
1546
1646
1746
1846
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......