A: Major water level adjustment

Loosen the inlet body by

turning slightly anti-clockwise,
Adjust it up or down to correct

position and tighten clockwise.

Re-insert the locker

Slide the locker to "unlock" position,

Move the stop float up/down.

B: Minor water level adjustment

Locker

Stop

Float

F

1x

1x

1x

2x

1x

Parts Supplied:

Inlet Valve

Button

1 - 7

Flush Valve

Flush Cone

"Y" scale

Note:

The Inlet Valve should be adjusted for the particular cistern into
which it is being installed.
Please refer to the 

Adjustment Instruction 

on 

page 5

 for the

X. Y settings.
The diagrams below show the detailed adjustment method.

1: Inlet Valve scale and adjustment settings

 "X" setting

Do not use bleach or bleach based cleaning products in the cistern, as these will cause damage to the seals.

     We cannot be held responsible or liable for any failure which results from the use of bleach based products.

Please read these instructions carefully to avoid damage to the valves, and to ensure correct installation.

Water temperature range +2C to +45C.
Water pressure 0.2 to 8 bar.

Bolt

Installation Instruction for

Dual Flush Cistern Fittings SP697

Inlet Valve Installation And Problem Solving

Содержание SP697

Страница 1: ...g installed Please refer to the Adjustment Instruction on page 5 for the X Y settings The diagrams below show the detailed adjustment method 1 Inlet Valve scale and adjustment settings X setting Do not use bleach or bleach based cleaning products in the cistern as these will cause damage to the seals We cannot be held responsible or liable for any failure which results from the use of bleach based...

Страница 2: ...istern Pull out the filter from the Inlet valve Filter Insert the filter back into the Inlet valve 4 Inlet Valve trouble shooting 2 Inlet Valve installation Inlet Valve 3 Filter cleaning Please clean periodically Clean by rinsing the filter Tighten the nut 2 7 F Stop Float Adjustment Rod Locker To decrease the water level use a screw driver to adjust the level of the Stop Float as shown The float ...

Страница 3: ...djust the push rod length see page 4 2 Flush Valve installation Note The Flush Valve should be adjusted for the particular cistern into which it is being installed Please refer to the Adjustment Instruction on page 6 for the full flush and half flush settings The diagrams below show the detailed adjustment method Flush Valve Installation And Problem Solving Overflow pipe Full flush adjustor flush ...

Страница 4: ...st come into contact with the flush valve but should not push down onto it unless the button is activated Loosen the lock nuts and unscrew the push rods to cut off the redundant section Please refer to the recommended length Z of push rods for particular cistern on page 7 Too long Too short 4 After installation check that the full flush and half flush are working correctly Please consult the troub...

Страница 5: ... tables for the settings For adjustment method please refer to the installation instruction on page 1 2 Inlet Valve Adjustment Instructions For 6L full flush and 3L half flush Cistern code X Y CC 1036 17 3 CM0007 20 3 15 B 27353 19 2 15 B 27349 17 2 SPH002 21 1 MAR 006 21 0 For 4 5L full flush and 2 6L half flush Cistern code X Y CC 1036 13 3 CM0007 17 3 15 B 27353 14 2 15 B 27349 16 2 SPH002 19 1...

Страница 6: ...e installation instruction on page 3 Flush Valve Adjustment Instructions For 6L full flush and 3L half flush Cistern code A B CC 1036 6 5 2 CM0007 6 5 1 5 15 B 27353 7 5 1 5 15 B 27349 7 1 5 SPH002 7 1 MAR 006 7 1 5 For 4 5L full flush and 2 6L half flush Cistern code A B CC 1036 4 5 5 CM0007 6 5 5 15 B 27353 3 5 2 15 B 27349 3 5 4 SPH002 7 5 MAR 006 6 5 Half flush float Should be set on the A mar...

Страница 7: ...th of push rods The push rods can be cut off to suit the particular cistern please refer to below table for the Z value Cistern code Z mm CC 1036 CM0007 15 B 27353 15 B 27349 SPH002 MAR 006 Push rod Z 197 197 159 207 181 200 ...

Отзывы: