13 PROGRAMMING
13.1 Precautions on Programming
491
13
13
PROGRAMMING
This chapter describes the program required for performing the positioning control with the RD75. When creating a program
required for the control, consider Start condition, Start time chart, Device setting, and the configuration of the whole control.
(According to the control to be performed, set data such as parameters, positioning data, block start data, and condition data
for the RD75, and create a setting program of control data and a start program of each control.)
13.1
Precautions on Programming
This section describes common precautions for writing data of the CPU module to the buffer memory of the RD75.
Reading/writing data
Using an engineering tool is recommended to set the data shown in this chapter (various parameters, positioning data, and
block start data). Because setting the data with programs requires many programs and devices, the execution becomes
complicated, and the scan times will increase. When changing positioning data during the continuous path control or
continuous positioning control, rewrite the data before positioning data four steps before is executed. If data has not been
rewritten when positioning data four steps before is executed, the data is processed as data that is not rewritten.
Restrictions on the execution interval of speed change
To change the speed successively using the speed change function or override function in the RD75, set 10ms or longer as
the interval between each speed change.
Measures against an overrun
Setting [Pr.12] Software stroke limit upper limit value and [Pr.13] Software stroke limit lower limit value of detailed parameter 1
can prevent an overrun. Note that this is valid only when the RD75 is operating normally. Set limit switches to ensure the
safety of the entire system. Establishing an external circuit through which the motor power turns off when a limit switch turns
on is recommended.
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......