9 PARAMETER SETTING
9.2 Module Parameters
319
9
*1 The basic parameter 3 setting is available only with an engineering tool.
Application setting
Set CPU error output mode setting of the RD75. For the RD75, do not change the setting from its default value ("0: Clear"). If
"1: Hold" is set, a hold error (error code: 1930H) occurs when the PLC READY signal [Y0] is turned on.
OPR detailed
parameter
OPR dwell time
0 to 65535 ms (default value: 0)
Page 414 [Pr.49] OPR dwell time
Setting for the movement amount after
near-point dog ON
Refer to the right item. (default value: 0)
Page 415 [Pr.50] Setting for the movement
amount after near-point dog ON
OPR acceleration time selection
• 0: Acceleration time 0 (default value)
• 1: Acceleration time 1
• 2: Acceleration time 2
• 3: Acceleration time 3
Page 416 [Pr.51] OPR acceleration time
selection
OPR deceleration time selection
• 0: Deceleration time 0 (default value)
• 1: Deceleration time 1
• 2: Deceleration time 2
• 3: Deceleration time 3
Page 416 [Pr.52] OPR deceleration time
selection
OP shift amount
Refer to the right item. (default value: 0)
Page 417 [Pr.53] OP shift amount
OPR torque limit value
1 to 3000 (default value: 300)
Page 418 [Pr.54] OPR torque limit value
Deviation counter clear signal output time
1 to 65535 ms (default value: 11)
Page 418 [Pr.55] Deviation counter clear
signal output time
Speed specification during OP shift
• 0: OPR speed (default value)
• 1: Creep speed
Page 418 [Pr.56] Speed specification
during OP shift
Dwell time during OPR retry
0 to 65535 ms (default value: 0)
Page 419 [Pr.57] Dwell time during OPR
retry
Setting of operation during uncompleted
OPR
• 0: Do not execute positioning control
(default value)
• 1: Execute the positioning control
Page 419 [Pr.58] Setting of operation
during uncompleted OPR
Basic parameter 3
Operation mode
• Q compatible mode (default value)
• Quick start mode
Extended parameter storage setting
• CPU (default value)
• Positioning module
Item
Setting range
Reference
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......