12 DATA USED FOR POSITIONING CONTROL
12.7 Monitor Data
445
12
[Md.4] Start No.
This area stores the start number.
■
Buffer memory address
For the buffer memory address of this area, refer to the following.
[Md.50] Start (year/month)
The start time (year/month) is stored with the BCD code. Monitor the value in hexadecimal.
■
Buffer memory address
For the buffer memory address of this area, refer to the following.
[Md.5] Start (date/hour)
The start time (date/hour) is stored with the BCD code. Monitor the value in hexadecimal.
■
Buffer memory address
For the buffer memory address of this area, refer to the following.
Start No.
Stored value
Positioning operation
• 1 to 600 (1H to 258H)
• 7000 (1B58H)
• 7001 (1B59H)
• 7002 (1B5AH)
• 7003 (1B5BH)
• 7004 (1B5CH)
JOG operation
9010 (2332H)
Manual pulse generator operation
9011 (2333H)
Machine OPR
9001 (2329H)
Fast OPR
9002 (232AH)
Current value change
9003 (232BH)
Simultaneous start
9004 (232CH)
Buffer memory configuration
Stored contents
Stored value
(1)
Year (tens place)
0 to 9
(2)
Year (ones place)
0 to 9
(3)
Month (tens place)
0 and 1
(4)
Month (ones place)
0 to 9
Buffer memory configuration
Stored contents
Stored value
(1)
Day (tens place)
0 to 3
(2)
Day (ones place)
0 to 9
(3)
Hour (tens place)
0 to 2
(4)
Hour (ones place)
0 to 9
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b0
b1
b2
b3
b4
(1)
(2)
(3)
(4)
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b0
b1
b2
b3
b4
(1)
(2)
(3)
(4)
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......