358
12 DATA USED FOR POSITIONING CONTROL
12.1 Types of Data
Block start data setting items
Values indicating the current values
Block start data must be set to perform Advanced positioning control. The following table lists the setting items for Block start
data.
Up to 50 points of Block start data can be set for each axis.
: Set as required
: Setting not required (Because this item is an irrelevant item, the set value is ignored. Set the value within the setting range,
such as the initial value.)
Checking block start data
Block start data is checked when the block start data starts.
Block start data setting
items
Block start
(normal start)
Condition start Wait start
Simultaneous
start
Repeated start
(FOR loop)
Repeated start
(FOR
condition)
[Da.11]
Shape (end/
continue)
[Da.12]
Start data No.
[Da.13]
Special start
instruction
[Da.14]
Parameter
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......