12 DATA USED FOR POSITIONING CONTROL
12.9 Interrupt Setting
485
12
[Pr.900] Interrupt factor setting
Specify the target (module) for the interrupt detection. The following table lists the available targets.
■
Buffer memory address
For the buffer memory address of this area, refer to the following.
■
Default value
The default value is 0: Do not detect.
[Pr.901] Axis No. for interrupt factor
Set the axis number in which an interrupt factor is detected.
■
Buffer memory address
For the buffer memory address of this area, refer to the following.
■
Default value
The default value is 0: All axes.
Interrupt factor setting
Detection timing
Setting value
Do not detect
OFF
ON
0
M code ON
1
Error detection
2
BUSY
3
Start complete
4
Positioning complete
5
Lower limit signal ([Md.30] External I/O signal)
ON
OFF
100
Upper limit signal ([Md.30] External I/O signal)
101
Drive unit READY ([Md.30] External I/O signal)
102
Stop signal ([Md.30] External I/O signal)
OFF
ON
103
External command signal ([Md.30] External I/O signal)
104
Zero signal ([Md.30] External I/O signal)
105
Near-point dog signal ([Md.30] External I/O signal)
106
Deviation counter clear signal ([Md.30] External I/O signal)
107
In speed control flag ([Md.31] Status)
200
Speed-position switching latch flag ([Md.31] Status)
201
Command in-position flag ([Md.31] Status)
202
OPR request flag ([Md.31] Status)
203
OPR complete flag ([Md.31] Status)
204
Position-speed switching latch flag ([Md.31] Status)
205
Warning detection ([Md.31] Status)
206
Speed change 0 flag ([Md.31] Status)
207
[Md.48] Deceleration start flag
300
[Md.61] Analysis complete flag
301
Axis No. for interrupt factor
Setting value
All axes
0
Axis 1
1
Axis 2
2
Axis 3
3
Axis 4
4
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......