12 DATA USED FOR POSITIONING CONTROL
12.6 Condition Data
439
12
12.6
Condition Data
The following figure shows the configuration of the condition data stored in the buffer memory of the RD75.
The axis 2 to axis 4 have the same configuration.
[Da.15] Condition target
Set the condition target according to each control.
The setting value for this area is stored in the same buffer memory address as that of [Da.16] Condition operator. Set this area
according to the buffer memory configuration.
■
Buffer memory address
For the buffer memory address of this area, refer to the following.
■
Default value
The default value is 0 for all the axes.
Condition target
Setting
value
Description
Device X
01H
Set the state (ON or OFF) of the I/O signals of the RD75 as a condition.
Device Y
02H
Buffer memory (1 word)
03H
Set the value stored in the buffer memory as a condition.
• Set 03H when the target buffer memory is 1 word (16 bits).
• Set 04H when the target buffer memory is 2 words (32 bits).
Buffer memory (2 words)
04H
Positioning data No.
05H
Select this item only for Simultaneous start.
Buffer memory configuration
Assignment
(1)
[Da.16] Condition operator
(2)
[Da.15] Condition target
No.10
Setting item
26190
26191
26192
26193
26194
26195
26196
26197
26198
26199
Buffer memory
address
No.2
Setting item
26110
26111
26112
26113
26114
26115
26116
26117
26118
26119
Buffer memory
address
Setting item
26100
Da.17
Address
Empty
Empty
Da.18
Da.19
b15
b0
b7
b8
b11
b12
Condition
operator
Da.15 Condition
target
26101
26102
26103
26104
26105
26106
26107
26108
26109
No.1
Axis 1 (start block 0)
Buffer memory
address
Da.16
Parameter 2
Parameter 1
Up to 10 condition data for each block No. can be set
(stored) in the buffer memory addresses shown on
the left.
One condition data is configured of the items shown in
the bold box.
Each axis has five start blocks (block 0 to 4).
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b0
b1
b2
b3
b4
(1)
(2)
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......