TC1784
Analog to Digital Converter (ADC)
User´s Manual
23-120
V1.1, 2011-05
ADC, V1.3
23.2.21
Access Protection
An access protection scheme has been implemented to avoid unintended modification
of some ADC control registers. It can be enabled by bits in register
that itself is
protected by the ENDINIT mechanism.
If the access protection is enabled for a group of registers and a write access occurs to
one of them, the write access is discarded, the targeted register is not modified, the
written data is ignored and the error flag ACCERR is set.
The protected ADC registers are located in one of the following register groups (registers
not listed below can not be protected):
•
Register group 0:
•
Register group 1:
,
•
Register group 2:
,
•
Register group 3:
•
Register group 4:
•
Register group 5:
,
,
,
Содержание TC1784
Страница 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Страница 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Страница 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...