![Infineon Technologies TC1784 Скачать руководство пользователя страница 323](http://html.mh-extra.com/html/infineon-technologies/tc1784/tc1784_user-manual_2055446323.webp)
TC1784
System Control Unit (SCU)
User´s Manual
3-140
V1.1, 2011-05
32-bit SCU, V1.18
WDT_CON0
WDT Control Register 0
(F000 05F0
H
)
Reset Value: FFFC 0002
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
REL
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
PW
HPW1
HPW0
LCK
END
INIT
rw
w
w
rwh rwh
Field
Bits
Type Description
ENDINIT
0
rwh
End-of-Initialization Control Bit
0
B
Access to Endinit-protected registers is
permitted (default after Application Reset)
1
B
Access to Endinit-protected registers is not
permitted
LCK
1
rwh
Lock Bit to Control Access to WDT_CON0
0
B
Register WDT_CON0 is unlocked
1
B
Register WDT_CON0 is locked
(default after Application Reset)
The actual value of LCK is controlled by hardware. It
is cleared after a valid Password Access to
WDT_CON0, and automatically set again after a valid
Modify Access to WDT_CON0. During a write to
WDT_CON0, the value written to this bit is only used
for the password-protection mechanism and is not
stored.
This bit must be cleared during a Password Access to
WDT_CON0, and set during a Modify Access to
WDT_CON0. That is, the inverted value read from
LCK always must be written to itself.
Содержание TC1784
Страница 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Страница 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Страница 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...