TC1784
System Control Unit (SCU)
User´s Manual
3-45
V1.1, 2011-05
32-bit SCU, V1.18
EXTCON
External Clock Control Register
(03C
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
DIV1
0
SEL1
N
SEL
EN1
rw
r
rw
rw
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
GPT
AINS
EL
SEL0
0
EN0
r
rw
rw
r
rw
Field
Bits
Type
Description
EN0
0
rw
External Clock Enable for EXTCLK0
0
B
No external clock is provided
1
B
The configured external clock is provided
SEL0
[5:2]
rw
External Clock Select for EXTCLK0
This bit field defines the clock source that is selected
as output for pin EXTCLK0.
0000
B
f
OUT
is selected for the external clock
0001
B
f
PLL
is selected for the external clock
0010
B
Reserved, do not use this combination
...
0110
B
Reserved, do not use this combination
0111
B
f
PLL_ERAY
is selected for the external clock
signal
1000
B
f
OSC
is selected for the external clock signal
1001
B
Reserved, do not use this combination
...
1110
B
Reserved, do not use this combination
1111
B
f
MT
from the ERAY module is selected for the
external clock
Содержание TC1784
Страница 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Страница 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Страница 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...