![Infineon Technologies TC1784 Скачать руководство пользователя страница 2076](http://html.mh-extra.com/html/infineon-technologies/tc1784/tc1784_user-manual_20554462076.webp)
TC1784
Micro Link Interface (MLI)
User´s Manual
22-127
V1.1, 2011-05
MLI, V2.0
PEI
7
rh
Parity Error Interrupt Flag
This flag is set when a parity error event has occurred.
The service request output that is activated is defined by
RINPR.MPPEIP.
MPEI
8
rh
Memory Protection Error Interrupt Flag
This flag is set when a memory protection event has
occurred.
The service request output that is activated is defined by
RINPR.MPPEIP.
DRAI
9
rh
Discarded Read Answer Interrupt Flag
This flag is set when the discarded read answer event
has occurred. This condition occurs if an Answer Frame
is received while none of the TRSTATR.RPx bits is set
(the Answer Frame was not expected).
The service request output that is activated is defined by
RINPR.DRAIP.
0
[31:10] r
Reserved
Read as 0; should be written with 0.
Field
Bits
Type Description