TC1784
Peripheral Control Processor (PCP)
User´s Manual
10-10
V1.1, 2011-05
PCP, V2.09
10.4.1.4 Register R6
Register R6 may also be used as a general-use register. Again however, there are some
instructions that use fields within R6. If the COPY or EXIT instructions are used, then the
field R6.CNT1 can optionally be used implicitly as a counter. If an EXIT instruction is
used that causes an interrupt, R6.SRPN and R6.TOS must be configured properly prior
to execution of the EXIT. If interrupt priority management is used, then R6.CPPN must
be set to the priority level at which the channel shall run at its next invocation, before the
EXIT is executed. The fields for R6 are shown below.
PCP Register R6
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
CPPN
SRPN
rw
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
TOS
GEN GEN
CNT1
rw
rw
rw
rw
Field
Bits
Type Description
CPPN
[31:24] rw
General-use/PCP Priority Number Posted to PICU
SRPN
[23:16] rw
General-use/Service Request Priority Number for
EXIT Interrupt
TOS
[15:14] rw
General-use/Type-of-Service for EXIT Interrupt
Upper bit of TOS is always forced to 0 when
transferred into the PCP SRNs, regardless of the
value specified in R6[15].
GEN
13
rw
General-use
GEN
12
rw
General-use
CNT1
[11:0]
rw
General-use/Outer Loop count for COPY
Instruction or EXIT Instruction
Содержание TC1784
Страница 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Страница 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Страница 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...