TC1784
FlexRay™ Protocol Controller (E-Ray)
User´s Manual
20-92
V1.1, 2011-05
E-Ray, V3.13
SUC Configuration Register 2 (SUCC2)
The Communication Controller accepts modifications of the register in
“DEFAULT_CONFIG” or “CONFIG” state only.
Note: The wakeup / startup noise time-out is calculated as follows:
The wakeup / startup noise time-out = pdListenTimeout • gListenNoise
= LT • (LTN+ 1)
SUCC2
SUC Configuration Register 2
(0084
H
)
Reset Value: 0100 0504
H
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
0
LTN
0
LT
r
rw
r
rw
Field Bits
Type Description
LT
[20:0]
rw
Listen Timeout
1)
(pdListenTimeout)
Configures wakeup / startup listen timeout in Microticks. The
range for wakeup / startup listen timeout (pdListenTimeout) is
1284 to 1283846 (504
H
to 139706
H
) Microticks
1) This bit can be updated in “DEFAULT_CONFIG” or “CONFIG” state only!
LTN
[27:24] rw
Listen Time-out Noise
(gListenNoise - 1)
Configures the upper limit for startup and wakeup listen timeout
in the presence of noise expressed as a multiple of the cluster
constant pdListenTimeout. The range of pdListenTimeout 2 to
16. LTN must be configured identical in all nodes of a cluster.
1
H
Listen Time-out Noise is equal 2
2
H
Listen Time-out Noise is equal 3
...
H
...
F
H
Listen Time-out Noise is equal 16
0
[23:21],
[31:28]
r
Reserved
Returns 0 if read; should be written with 0.
Содержание TC1784
Страница 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Страница 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Страница 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...