Emergency Stop Flag
This bit indicates if an emergency stop condition has
occurred.
0
B
An emergency stop has not occurred
1
B
An emergency stop has occurred and signal
emergency stop becomes active (if MODE = 0)
EMSFM
[25:24]
w
Emergency Stop Flag Modification
This bit field set or clear flag EMSF via software.
00
B
EMSF remains unchanged
01
B
EMSF becomes set
10
B
EMSF becomes cleared
11
B
EMSF remains unchanged
EMSFM is always read as 00
B
.
0
[15:3],
[23:17],
[31:26]
r
Reserved
Read as 0; should be written with 0.
Field
Bits
Type Description