Micro Link Interface (MLI)
User´s Manual
22-63
V1.1, 2011-05
MLI, V2.0
22.2.6
Receiver Events
The MLI receiver can generate the following MLI events:
22.2.6.1 Discarded Read Answer Event
A discarded read answer received event is generated if an Answer Frame has been
received and the read pending flag TRSTATR.RPx of its correspondent pipe is 0.
Although named “discarded”, the received data is available in the receiver data register
until it is overwritten by the next incoming data.
Figure 22-43 Discarded Read Answer Event Logic
Table 22-8
MLI Receiver Interrupts
Events
Events combined to
See
Discarded Read Answer
Discarded Read Answer
Memory Access Protection Error
Memory Access Protection/
Parity Error
Parity Error
Normal Frame Correctly Received
Normal Frame Received
Move Engine Access Terminated
Interrupt Command Frame
Interrupt Command Frame
Command Frame Received on Pipe 0 Command Frame Received
Command Frame Received on Pipe 1
Command Frame Received on Pipe 2
Command Frame Received on Pipe 3
Discarded
Read Answer
Event
DRAIE
RIER
DRAIR
DRAI
RISR
Set
MCA06314a_mod
Software
Clear
DRAIP
3
RINPR
To SR0
To SR7
….
….
Содержание TC1784
Страница 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Страница 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Страница 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...