TC1784
Micro Second Channel (MSC)
User´s Manual
18-11
V1.1, 2011-05
MSC, V1.40
The following formula determines the number of
t
FCL
cycles of a data frame: All
parameters (bits and bit fields) are located in register DSC.
(18.1)
Note that in the formula above, PPD must be set to 2 when DSC.PPD
≤
00010
B
.
Passive Time Frames
A passive time frame has the length defined by the five data frame parameters according
. They are generated only in Data Repetition Mode. Under special
conditions (command frame insertion), passive time frames can be shortened (see
During passive time frames, the data output SO have to be considered as invalid at the
receiving device and the clock output FCL may toggle or not (as selected by bit
OCR.CLKCTRL). The ENL and ENH enable signals remain at low level during a passive
time frame.
Number of cycles = NDBL + NDBH + PPD