![Infineon Technologies TC1784 Скачать руководство пользователя страница 1275](http://html.mh-extra.com/html/infineon-technologies/tc1784/tc1784_user-manual_20554461275.webp)
TC1784
Controller Area Network Controller (MultiCAN)
User´s Manual
19-19
V1.1, 2011-05
MLI, V2.0
impossible, and that the CAN bus is blocked (e.g. if the suspended CAN module just
sends a dominant level). A reset operation must be executed to leave Hard Suspend
Mode.
•
The current action is finished (Soft Suspend Mode):
The module clock
f
CLC
keeps running. Module functions are stopped automatically
after internal actions have been finished (for example, after a CAN frame has been
sent out). The end of the internal actions is indicated to the fractional divider by a
suspend mode acknowledged signal. Due to this behavior, the communication
network is not blocked. Furthermore, all registers are accessible for read and write
actions. As a result, the debugger can stop the module actions and modify registers.
These modifications are taken into account after the Suspend Mode is left.
The Hard Suspend Mode can be enabled/disabled only for the complete MultiCAN
module. The Soft Suspend Mode can be individually enabled for each CAN node.
The fractional divider disables module clock
f
CAN
only if all CAN nodes signal that they
can be suspended. A CAN node that is not active can always be suspended.
Содержание TC1784
Страница 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Страница 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Страница 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Страница 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...