Remote Operation
Publication 31470-001, Rev C, November 2, 2017
3-55
Syntax:
CALCulate<channel 1 to 4>:LIMit:LOWer
space
<numeric value in dBm or dB from -299.99 to 299.99>
Example:
CALC1:LIM:LOW -50.0
! SETS CHANNEL 1 LOWER LIMIT LINE TO -50.0 DBM
Description:
This command specifies the lower limit line power level. The value should allow for any offset
values currently in use. The default value is -299.99 dB or dBm.
Syntax:
CALCulate<channel 1 to 4>:LIMit:UPPer
space
<numeric value in dBm or dB from -299.99 to 299.99>
Example:
CALC1:LIM:UPP 17.0
! SETS CHANNEL 1 UPPER LIMIT LINE TO +17.0 DBM
Description:
This command specifies the upper limit line power level. The value should allow for any offset
values currently in use. The default value is +299.99 dB or dBm.
Syntax:
CALCulate<channel 1 to 4>:LIMit:STATe
space
<ON | OFF>
Example:
CALC1:LIM:STAT ON
! ENABLES CHANNEL 1 UPPER AND LOWER LIMIT CHECKING
Example 2:
CALC1:LIM:STAT?
! QUERIES THE CHANNEL 1 LIMIT CHECKING STATE
Response:
0 = off ; 1 = on
Description:
This command activates and deactivates the limit line checking. The default condition is OFF.
Query form is available.
Содержание 8650B Series
Страница 3: ...Series 8650B Universal Power Meters Publication 31470 001 Rev C November 2 2017 iii ...
Страница 18: ......
Страница 32: ......
Страница 78: ......
Страница 236: ......
Страница 244: ......
Страница 258: ......
Страница 263: ...Menu Structure Publication 31470 001 Rev C November 2 2017 D 3 Figure D 3 Modulation Sensor B Setup Menu Structure ...
Страница 265: ...Menu Stucture Publication 31470 001 Rev C November 2 2017 Page D 5 Figure D 4 Meter Setup Menu Structure ...
Страница 267: ...Publication 31470 001 Rev C November 2 2017 Last page of the document ...