Series 8650B Universal Power Meters
2-8
Publication 31470-001, Rev C, November 2, 2017
Strip Chart
The Strip Chart function plots measurements on the screen over a fixed period or continuously. The X-axis
displays time from the start of a measurement to a selective period of 1 to 200 minutes. While running, the
adaptive auto-scaled high and low plotting limits are displayed. While paused, the cursor can be used to review
plotted values.
1.
From the Power Meter Configuration menu, move the cursor to the
Strip Chart
option and press
[Config]
(See Figure 2-4).
2.
Press
[Select Source]
. The choices for measuring sources are Lines 1 through 4. If any line is set for data
gathering, it will not be displayed here.
3.
Press
[Sample Rate]
. The choices are from 1 sample per minute to 5 samples per second.
4.
Toggle between
[Hold Bfr]
to stop sampling when the buffer is full, or
[Rot Bfr]
to set the Strip Chart
display to update continuously with new samples after the buffer is initially full while discarding the
same number of beginning samples.
5.
Press
[OK]
to accept the changes or
[Cancel]
to cancel the changes, and return to the Power Meter
Configuration menu.
Figure 2-4: Strip Chart Illustration
Содержание 8650B Series
Страница 3: ...Series 8650B Universal Power Meters Publication 31470 001 Rev C November 2 2017 iii ...
Страница 18: ......
Страница 32: ......
Страница 78: ......
Страница 236: ......
Страница 244: ......
Страница 258: ......
Страница 263: ...Menu Structure Publication 31470 001 Rev C November 2 2017 D 3 Figure D 3 Modulation Sensor B Setup Menu Structure ...
Страница 265: ...Menu Stucture Publication 31470 001 Rev C November 2 2017 Page D 5 Figure D 4 Meter Setup Menu Structure ...
Страница 267: ...Publication 31470 001 Rev C November 2 2017 Last page of the document ...