Front Panel Operation
Publication 31470-001, Rev C, November 2, 2017
2-17
2.3.2.1
Line Configuration
Select the line to be configured by pressing the corresponding
[Line n]
softkey. The menu in Figure 2-12 will
display. The current configuration of the selected source displays in the large window at the bottom of the
screen.
Figure 2-12: Data Line Configuration Menu
Source:
1.
Press
[Select Source]
to enable the cursor in the Source field.
2.
Move the highlight with the cursor keys to select the desired Source.
a.
A B
:
This corresponds to sensor
A
and
B
inputs. The Data field will show the line configuration
possibilities when selecting the corresponding source input. When selecting source
A
, the Data field
will read
A, A/B
and
A-B
. When selecting source
B
, the Data field will read
B, B/A
and
B-A
.
b.
Line
n
:
When selecting Line
n
in the Source field, the Data field will change to
Min/Max
. Configure the
selected line number to be the source. For example, use the selected line to display the
minimum/maximum values of another line (Line
n
). The only line numbers that will be available for
selection are those which have already been configured and are not configured to show min/max
values of other lines. If selecting line number to show the min/max values of another line but the
line is not available in the source list, go back and reconfigure the missing line. It may not be
configured at all, or it may be configured to display the min/max of another line.
c.
Other
:
This selection changes the Data field to copy another line into the line number configuring. The Data
field will change to indicate the lines, such as
n1—>n2
, meaning that line
n1
will be copied into line
n2
(the line configuration). This option may be useful, for example, if changing a line configuration is
required while saving its previous configuration elsewhere; select
Other
and copy the configuration
to a different line and retain the configuration on the new line.
Содержание 8650B Series
Страница 3: ...Series 8650B Universal Power Meters Publication 31470 001 Rev C November 2 2017 iii ...
Страница 18: ......
Страница 32: ......
Страница 78: ......
Страница 236: ......
Страница 244: ......
Страница 258: ......
Страница 263: ...Menu Structure Publication 31470 001 Rev C November 2 2017 D 3 Figure D 3 Modulation Sensor B Setup Menu Structure ...
Страница 265: ...Menu Stucture Publication 31470 001 Rev C November 2 2017 Page D 5 Figure D 4 Meter Setup Menu Structure ...
Страница 267: ...Publication 31470 001 Rev C November 2 2017 Last page of the document ...