Series 8650B Universal Power Meters
2-18
Publication 31470-001, Rev C, November 2, 2017
d.
Off
:
Select this option to turn the line off. When a line is turned off, it will not be available as a source for
Line
n
. For example, if Line 4 is turned off, setting Line 3 cannot read the minimum/maximum values
of line 4.
Data
1.
After selecting the source for the line being configured, press
[Select Data]
to enable the cursor in the Data
field.
2.
Move the selection highlight with the cursor keys to the configuration of your choice.
a.
When selecting source
A
, the Data field will read
A
,
A/B
and
A-B
. When selecting source
B
, the Data field
will read
B
,
B/A
and
B-A
.
b.
Other measurements that can be selected for Modulation Sensors are
Peak Hold
,
Crest Factor
, and
Mean & Standard Deviation
.
dB/mW
This selection toggles the line units between
dB
and
mW
. It can be changed at any time to display the opposite
units.
Config
Use the Config selection to set the measurement
Resolution
, to
Set Limits
, and to set the
Bar Graph
option.
Lines configured with Statistics can be configured only for Resolution; the Set Limits and Bar Graph options will
not display for these lines.
1.
Press
[Config]
and use the cursor keys to set the Resolution of the input. The resolution will be displayed in
the large window at the bottom of the screen. Adjust the resolution with the cursor keys to the desired
level. The range is 0 to 3 decimal places.
2.
Press
[Set Limits]
to set the upper and lower measurement limits, or to turn the limits off.
a.
Press
[High]
and set each digit of the high limit with the cursor keys.
b.
Press
[Low]
and set each digit of the low limit with the cursor keys.
c.
Press
[Limits Off]
to disable use of the limits. Press
[High]
or
[Low]
again to enable and set the limits.
3.
Press
[Bar Graph]
to set the utilization of the bar graph scale.
a.
The menu will display as described above for Set Limits.
b.
Follow the Set Limits procedure above to set the bar graph scale, or to disable the bar graph.
c.
The upper and lower limits of the bar graph will be displayed in the Main menu as brackets with the
current measurement shown as a horizontal bar between the brackets (e.g.,[ ]).
4.
Press
[OK]
to save all changes and return to the Configure Display screen, or
[Cancel]
to leave the
configuration without saving any changes.
Содержание 8650B Series
Страница 3: ...Series 8650B Universal Power Meters Publication 31470 001 Rev C November 2 2017 iii ...
Страница 18: ......
Страница 32: ......
Страница 78: ......
Страница 236: ......
Страница 244: ......
Страница 258: ......
Страница 263: ...Menu Structure Publication 31470 001 Rev C November 2 2017 D 3 Figure D 3 Modulation Sensor B Setup Menu Structure ...
Страница 265: ...Menu Stucture Publication 31470 001 Rev C November 2 2017 Page D 5 Figure D 4 Meter Setup Menu Structure ...
Страница 267: ...Publication 31470 001 Rev C November 2 2017 Last page of the document ...