Remote Operation
Publication 31470-001, Rev C, November 2, 2017
3-57
MEMory:UNIT
Syntax:
MEMory[:TABLe]:UNIT
space
<choice of units DBM or Watts>
Example:
MEM:UNIT DBM
! SETS ANALOG OUT LOG POWER UNITS
Example 2:
MEM:UNIT W
! SETS ANALOG OUT LINEAR POWER UNITS
Description:
This command selects between one of two configurations: log units or linear units. In either
case the voltage output will be numerically linear. Be sure to set the units control properly
(DBM or W) before trying to set the numeric values. This command must be preceded by the
Analog Output memory selection, MEMory:SELect ANALOGout.
MEMory:POWer
Syntax:
MEMory[:TABLe]:POWerspace<start value from -80 to +20 dBm>comma<stop value from -80 to +20 dBm>
Syntax 2:
MEMory[:TABLe]:POWerspace<start value from 0 to 0.01 Watts>comma<stop value from 0 to 0.01 Watts>
Example:
MEM:POW -40,20
! SETS ANALOG OUT POWER RANGE FROM -70 TO 20 DBM
! FOLLOWING ANALOG OUTPUT LOG UNITS CONFIGURATION
Example 2:
MEM:POW 1E-4,1E-2
! SETS ANALOG OUT POWER RANGE FROM 0.0001 TO 0.01 WATTS
! FOLLOWING ANALOG OUTPUT LINEAR UNITS CONFIGURATION
Description:
If log units are selected for analog output control this command selects the beginning and end
points of the power levels, in dBm, which will be assigned corresponding voltages at the analog
output. If linear units are selected for analog output control this command selects the beginning
and end points of the power levels, in Watts, which will be assigned corresponding voltages at
the analog output. This command must be preceded by the Analog Output units configuration,
MEMory:UNIT.
MEMory:VOLTage
Syntax:
MEMory[:TABLe]:VOLTagespace<start value from 0 to +10 V>comma<stop value from 0 to +10 V>
Example:
MEM:VOLT 2,8
! SETS THE ANALOG OUT VOLTAGE RANGE FROM 2 TO 8 VOLTS
! CORRESPONDING TO THE CONFIGURED POWER RANGE
Description:
This command selects the beginning and end points of the voltage levels desired to be present
at the Analog Output. These voltages correspond to the power end points that are defined by
MEMory:POWer. This command is not units dependent. This command must be preceded by
the Analog Output power level configuration, MEMory:POWer.
OUTPut:ANAlog
Syntax:
OUTPut[:BNC]:ANAlog[:STATe]
space
<ON | OFF>
Example:
OUTP:ANA ON
! ENABLES THE ANALOG OUT FUNCTION
! A OR B DEPEDENT ON THE CURRENT ACTIVE CHANNEL
Description:
This command enables and disables the Analog Output channel that is currently active as
defined by MEMory:CHANnel. The Analog Output will not operate unless this control is set to
ON. The Analog Output channel should be fully configured prior to enabling using the
MEMory:SELect, MEMory:UNIT, MEMory:POWer, and MEMory:VOLTage commands.
Содержание 8650B Series
Страница 3: ...Series 8650B Universal Power Meters Publication 31470 001 Rev C November 2 2017 iii ...
Страница 18: ......
Страница 32: ......
Страница 78: ......
Страница 236: ......
Страница 244: ......
Страница 258: ......
Страница 263: ...Menu Structure Publication 31470 001 Rev C November 2 2017 D 3 Figure D 3 Modulation Sensor B Setup Menu Structure ...
Страница 265: ...Menu Stucture Publication 31470 001 Rev C November 2 2017 Page D 5 Figure D 4 Meter Setup Menu Structure ...
Страница 267: ...Publication 31470 001 Rev C November 2 2017 Last page of the document ...