Remote Operation
Publication 31470-001, Rev C, November 2, 2017
3-17
Table 3-3: SCPI Command Syntax
Command Syntax
Function
Section
SENSe<sensor 1 or 2>:CONFig:BAP
Enable BAP mode on the specified sensor
SENSe<sensor 1 or 2>:CONFig:BAP:BEEXcludespace<samples>
Set the number of BAP mode burst end exclude
samples
SENSe<sensor 1 or 2>:CONFig:BAP:BEEXclude?
Query the number of BAP mode burst end exclude
samples
SENSe<sensor 1 or 2>:CONFig:BAP:BSEXclude?space<samples>
Set the number of BAP mode burst start exclude
samples
SENSe<sensor 1 or 2>:CONFig:BAP:BSEXclude?
Query the number of BAP mode burst start exclude
samples
SENSe<sensor 1 or 2>:CONFig:BAP:BDTolerancespace<dropout>
Set the BAP mode burst dropout tolerance duration
SENSe<sensor 1 or 2>:CONFig:BAP:BDTolerance?
Query the current BAP mode burst dropout
tolerance duration
SENSe<sensor 1 or 2>:CONFig:CW
Enable CW mode on the specified sensor
SENSe<sensor 1 or 2>:CONFig:MAP[:SYNChronized]
Enable synchronized MAP mode on the specified
sensor
SENSe<sensor 1 or 2>:CONFig:MAP:UNSYnchronized
Enable unsynchronized MAP mode on the specified
sensor
SENSe<sensor 1 or 2>:CONFig:PAP
Enable PAP mode on the specified sensor
SENSe<sensor 1 or 2>:CONFig:PAP:DCYClespace<Duty Cycle>
Set the PAP mode duty cycle value on the specified
sensor
SENSe<sensor 1 or 2>:CONFig:PAP:DCYCle?
Query the PAP mode duty cycle
SENSe<sensor 1 or 2>:CORRection:EEPROM:TYPE?
Query the sensor eeprom type
SENSe<sensor 1 or 2>:CORRection:EEPROM:FREQuency?
Query the sensor eeprom frequency table
SENSe<sensor 1 or 2>:CORRection:EEPROM:CALFactor?
Query the sensor eeprom cal factor table
SENSe<sensor 1 or 2>:CORRection:FREQuency[:CW-FIXed]space
<frequency in Hz>
Set the sensor compensation frequency
SENSe<sensor 1 or 2>:CORRection:OFFSet:COLLect
Set the current sensor reading as the offset value
SENSe<sensor 1 or 2>:CORRection:OFFSet[:MAGnitude]space
<offset value in dB>
Set the sensor offset value in dB
SENSe<sensor 1 or 2>:CORRection:OFFSet:STATespace
<ON | OFF>
Enable/Disable the sensor offset correction
SENSe<sensor 1 or 2>:CORRection:VPROpf[:STATe]space
<ON | OFF>
Enable/Disable the V
PROP
F correction
SENSe<sensor 1 or 2>:GATE:MODEspace
<OFF, GATE, TRIGger, or EDGE>
Set the sensor Time Gating mode
SENSe<sensor 1 or 2>:GATE:POLarityspace<INVert or NINVert>
Set the Time Gating mode trigger polarity
SENSe<sensor 1 or 2>:GATE:DELayspace<time>
Set the Time Gating mode delay time
SENSe<sensor 1 or 2>:GATE:DURationspace<time>
Set the Time Gating mode duration period
SENSe<sensor 1 or 2>:GATE:HOLDoff<time>
Set the Time Gating mode hold-off time
SENSe<sensor 1 or 2>:TEMPerature?
Query the sensor temperature (in centigrade)
SENSe<sensor 1 or 2>:TRIGger:SOURcespace
<peak sensor triggering; INTernal, EXTernal or CW>
Set the Peak sensor trigger mode
SENSe<sensor 1 or 2>:TRIGger:DELay[:MAGnitude]:space
<peak sensor sample delay in seconds>
Set the Peak sensor delay value in seconds
Содержание 8650B Series
Страница 3: ...Series 8650B Universal Power Meters Publication 31470 001 Rev C November 2 2017 iii ...
Страница 18: ......
Страница 32: ......
Страница 78: ......
Страница 236: ......
Страница 244: ......
Страница 258: ......
Страница 263: ...Menu Structure Publication 31470 001 Rev C November 2 2017 D 3 Figure D 3 Modulation Sensor B Setup Menu Structure ...
Страница 265: ...Menu Stucture Publication 31470 001 Rev C November 2 2017 Page D 5 Figure D 4 Meter Setup Menu Structure ...
Страница 267: ...Publication 31470 001 Rev C November 2 2017 Last page of the document ...