Series 8650B Universal Power Meters
2-2
Publication 31470-001, Rev C, November 2, 2017
2.2.1
Front Panel Layout Descriptions
The following are the descriptions based on the call out numbers for Figure 2-1.
1 - Dedicated Hardkeys
The dedicated hardkeys are located on the right side of the front panel and function as described below.
In this manual, instructions to press a dedicated hardkey are with the appropriate key title in bold
uppercase enclosed in brackets, such as ‘press
[CAL/ZERO]
to calibrate a power sensor’
Cursor Keys
These four keys are arranged in a diamond pattern and move the highlighted item (cursor) in the
display to the desired location. A small diamond symbolizing the cursor keys appears in menus, with
an arrow in the keys that are effective for that menu. If more than one field is highlighted, the cursor
pattern will be located nearest the one that will be activated when the cursor keys are pressed.
CAL/ZERO
This key is for zeroing and calibration of a power sensor. All active sensors should be zeroed
whenever any sensor is added or removed, whether it is calibrated or not.
FREQ
This key specifies the frequency of an input signal so that the power meter can apply the frequency
specific cal factor from the sensor EEPROM to the measurement.
If the frequency of the input signal changes so often that it is impractical to keep entering the
frequency with the FREQ key, the frequency information can be conveyed to the 8650B by the use of
a voltage input that is proportional to frequency (See the V
PROP
F connector on the rear panel). When
the 8650B is controlled remotely, the frequency information can be sent over the bus.
HELP
Help screens describe the current display and present your options. From any menu, press
[HELP]
to
display the associated Help screen. Press the up or down cursor key, if shown, to scroll the help
screen up or down one line at a time. Press
[EXIT HELP]
to leave the Help screen and return to the
current menu.
I/O (Power)
This push-push switch turns main power on and off. The LED above the power switch will be green
when the unit is ON, and will turn yellow indicating the standby mode when the power switch is OFF
with the main ac power still connected. The LED will be OFF when the ac power is disconnected. All
user setting and sensor calibrations will be automatically stored in non-volatile memory for recall
when ac power is turned off with the front panel on/off switch.
Содержание 8650B Series
Страница 3: ...Series 8650B Universal Power Meters Publication 31470 001 Rev C November 2 2017 iii ...
Страница 18: ......
Страница 32: ......
Страница 78: ......
Страница 236: ......
Страница 244: ......
Страница 258: ......
Страница 263: ...Menu Structure Publication 31470 001 Rev C November 2 2017 D 3 Figure D 3 Modulation Sensor B Setup Menu Structure ...
Страница 265: ...Menu Stucture Publication 31470 001 Rev C November 2 2017 Page D 5 Figure D 4 Meter Setup Menu Structure ...
Страница 267: ...Publication 31470 001 Rev C November 2 2017 Last page of the document ...