Series 8650B Universal Power Meters
3-16
Publication 31470-001, Rev C, November 2, 2017
Table 3-3: SCPI Command Syntax
Command Syntax
Function
Section
CALCulate<channel 1 to 4>:MAXimum[:MAGnitude]?
Query the channel maximum value in dBm
CALCulate<channel 1 to 4>:MINimum:STATespace<ON | OFF>
Enable/Disable the channel min. value monitoring
CALCulate<channel 1 to 4>:MINimum[:MAGnitude]?
Query the channel minimum value in dBm
CALCulate<channel 1 to 4>:REFerence:STATespace<ON | OFF>
Enable/Disable the channel reference function for
relative measurements
CALCulate<channel 1 to 4>:REFerence[:MAGnitude]space
<dB offset value from -299.999 to 299.999>
Set the channel reference offset value in dB
CALCulate<channel 1 to 4>:REFerence:COLLect
Set the current channel reading as reference value
CALCulate<channel 1 to 4>:SFUNctions:STATespace<ON |OFF>
Enable/Disable the channel Statistical functions
CALCulate<channel 1 to 4>:SFUNctions:DATa?
Query the channel Statistical measurements
CALCulate<channel 1 to 4>:STATespace<ON | OFF>
Enable/Disable the channel measurement
CALCulate<channel 1 to 4>:UNIT[:POWer]space
<data units selection, DBM or Watt>
Configure the channel to report power
measurements in linear units or log units
CALibrate<sensor 1 or 2>[:SENSor]
Calibrate the sensor
CALibrate<sensor 1 or 2>:STATe?
Query the sensor for calibration status
CALibrate<sensor 1 or 2>:ZERO
Zero the sensor
FETCh<channel 1 to 4>?
Return the post-processed measurement data from
the active channel(s)
INITiate[:IMMediate]
Initiate the instrument triggering cycle
INITiate:CONTinuousspace<ON | OFF>
Enable/Disable the continuous instrument triggering
cycle reset
MEASure<channel 1 to 4>[:SCALar:POWer]?
Initiate, trigger, and return the channel
measurement data
MEMory[:TABLe]:CHANnelspace<channel 1 or 2>
Set the active Analog Output channel
MEMory[:TABLe]:FREQuency<start frequency>
Set the V
PROP
F correction start frequency in Hz
MEMory[:TABLe]:POWerspace
<start value in dBm>comma<stop value in dBm>
Set the Analog Output input power range in dBm
MEMory[:TABLe]:POWerspace
<start value in Watts>comma<stop value in Watts >
Set the Analog Output input power range in Watts
MEMory[:TABLe]:SELectspace
<ANALOGout,VPROPF1, or VPROPF2>
Select Memory Table for Analog Out configuration
Select Memory Table for V
PROP
F configuration
MEMory[:TABLe]:SLOPespace<Volts per Hz>
Set the V
PROP
F correction slope in V/Hz
MEMory[:TABLe]:UNITspace< DBM or Watt>
Set the Analog Output power unit
MEMory[:TABLe]:VOLTagespace
<start value in Volts>comma<stop value in Volts>
Set the Analog Output voltage range that
corresponds to the input power range
OUTPut[:BNC]:ANAlog[:STATe]space<ON | OFF>
Enable/Disable the Analog Output function
OUTPut:ROSCillator[:STATe]space<ON | OFF>
Enable/Disable the Reference Oscillator
READ<channel 1 to 4>[:POWer]?
Trigger and return the channel measurement data
SENSe<sensor 1 or 2>:AVERage:COUNtspace<averaging value>
Set the sensor Averaging factor
SENSe<sensor 1 or 2>:AVERage:COUNt:AUTOspace<ON | OFF>
Enable/Disable the sensor Auto-average mode
SENSe<sensor 1 or 2>:AVERage:TCONtrolspace
<data acquisition averaging method; MOVing or REPeat>
Set the sensor Averaging method
SENSe<sensor 1 or 2>:CONFig?
Query the sensor configuration
Содержание 8650B Series
Страница 3: ...Series 8650B Universal Power Meters Publication 31470 001 Rev C November 2 2017 iii ...
Страница 18: ......
Страница 32: ......
Страница 78: ......
Страница 236: ......
Страница 244: ......
Страница 258: ......
Страница 263: ...Menu Structure Publication 31470 001 Rev C November 2 2017 D 3 Figure D 3 Modulation Sensor B Setup Menu Structure ...
Страница 265: ...Menu Stucture Publication 31470 001 Rev C November 2 2017 Page D 5 Figure D 4 Meter Setup Menu Structure ...
Страница 267: ...Publication 31470 001 Rev C November 2 2017 Last page of the document ...