IGNITION SYSTEM
CHECKING THE CDI UNIT
Measure:
CDI unit output peak voltage
Below specification
Replace the
CDI unit.
NOTE:
Before measuring CDI unit output peak
voltage, make sure that no abnormality is
observed on the charge coil and the pulser
coil.
CDI unit output peak voltage
Orange (O) - Black (B)
r/min.
Cranking
1,500
3,500
Opened
Closed
D.C.V
53.2
140
168
168
Peak voltage adaptor:
YU-39991/90890-03172
8-13
Summary of Contents for F6AMH
Page 68: ...MAINTENANCE SPECIFICATIONS OUTBOARD DIMENSIONS F6AMH F6BMH F8CMH 2 15 ...
Page 72: ...MAINTENANCE SPECIFICATIONS OUTBOARD DIMENSIONS F6AMH F6MH F8CMH F8MH 2 17 ...
Page 76: ...MAINTENANCE SPECIFICATIONS OUTBOARD DIMENSIONS F8CW 2 19 ...
Page 140: ...GENERAL LUBRICATION POINTS Apply Water resistant grease NOTE Use a grease gun 3 25 ...
Page 142: ...GENERAL 3 26 ...
Page 143: ...GENERAL ALLGEMEINES GENERAL 3 26 ...
Page 502: ......