ZCM-11, ZCM-11/U TIME PROGRAMMER
WEEK’S - SINGLE-CHANEL
INSTRUCTION MANUAL
Zak
ł
ad Mechaniki i Elektroniki
ZAMEL
sp.j.
J.W. Dzida, K.
Ł
odzi
ń
ska
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamelcet.com
, e-mail: [email protected]
APPEARANCE
FEATURES
TECHNICAL DATA
DESCRIPTION
ZCM-11
Power supply terminals: A1, A2
Input rated voltage:
ZCM-12: 230 V AC
~
(-15 ÷ +10 %)
ZCM-12/U: 24 ÷ 250 V AC, 30 ÷ 300 V DC
Nominal frequency: 50 / 60 Hz
Rated power consumption: 2 W / 14 VA
Number of channels: 1
Program quantity: 400 (200 On/Off pairs)
Program: daily, week’s
Operating modes: manual, automatic, random, impulse
Change of season summer/ winter: automatic, manual
Colour of LCD panel lighting: amber
Input: yes
Accuracy of time measurement: max ±1 s / 24 h at temp. 25 °C
Time of clock maintenance: 3 years
Time of programme maintenance: 10 years
Clamps of release system: IN, IN, IN, IN
Receiver input (supply) terminals: 11, 12, 14
Output relay parameters: 1 NO/NC-16 A/250 V AC1 4000 VA
Number of terminal clamps: 12
Section of connecting cables: 0,2 ÷ 2,50 mm
2
Ambient temperature range: -20 ÷ +60
o
C
Operating position: freely
Mounting: rail TH 35 (PN-EN 60715)
Protection degree: IP20 (PN-EN 60529)
Protection level: II
Overvoltage category: II
Pollution degree: 2
Dimensions: double-modular (35 mm) 90x35x66 mm
Weight: 0,140 kg
Reference standards: PN-EN 60730-1; PN-EN 60730-2-7
PN-EN 61000-4-2,3,4,5,6,11
●
Week’s cycle control in dependence of
the current hour,
●
Double-module casing with a protection
flap,
●
Random op mode, additional control
input IN,
●
Many programmes enabling various
applications,
●
LCD display illumination,
●
Mounted on TH 35 rail.
Programmable control timers are de-
signed for time functions execution in
automatics and control systems. Week’s
programmer controls the output relay in de-
pendence of program settings (day, hour).
The device is
fi
tted with some additional
functions, among other things the random
function that is used for the operating mode
changing by means of an external push
button. It is possible to mount the device
on TH 35 rail and seal it if needed. A simple
menu layout and an ergonomic keyboard
enable easy and intuitive unit operating.
The construction of the system guar-
antees supporting of all the settings
with battery energy when the electric
power supply is off.
CAUTION:
Before installing
the device in the
switchboard
or starting the
system operation
in order to pro-
gramme it, the
battery security
separator should
be removed against
discharging.
The device should be connected
to a singlephase system accor-
ding to current standards. The
device connections will be descri-
bed in this manual. Only quali
fi
ed
electricians are allowed to mount,
connect and adjust the device. It is necessary
to read this manual and know the unit functions
before the device mounting. Do not disassembly
the device casing or you will lose any warranty
rights and expose yourself to the electric shock
hazard. Before mounting operation make sure
of disconnecting the connection wires from the
electric network. Use a cross-head screwdriver
of 3.5 mm diameter to mount the device. The
relay should be carried, stored and used in an
appropriate way. Do not mount the device in
case of any device parts lack, damage or defor-
mation. In case of malfunction please notify the
manufacturer.
CAUTION
VER. 002_21.09.2009
Winter/summer time
Random mode
Manual mode
Automatic mode
Week’s day
Relay state
Info
fi
eld
Current time (hh:mm:ss)
Power terminals
(A1, A2)
LCD display
Control buttons
Relay output terminals
(12, 12, 11, 11, 14, 14)
Trigger terminals
(IN, IN, IN, IN)
The symbol means selective collecting
of electrical and electronical equipment.
It is forbidden to put the used equipment
together with other waste.
DESCRIPTION
MAIN MENU
DATE SETTING
- Current date setting; entry after pressing OK;
YEAR - choose adequate year with cursors
con
fi
rm with OK, range of
years: 2000÷2099;
MONTH - choose month with cursors
con
fi
rm with OK;
DAY - choose day with cursors
con
fi
rm with OK; the system has a protec-
tion against introducing incorrect parameter of a day for a given month (it
takes into account leap years and it automatically calculates the day of the
week on the basis of an arranged date);
Con
fi
rmation causes movement to a date setting window and set-up of cur-
rent summer/ winter time - if the option
is arranged.
It is possible to exit every submenu window in any moment without sav-
ing settings by pressing the button or .
Description of elements and messages displayed
- days of week
- day,
- year
- transmitter’s status
- program setting
- automatic mode
- current time setting and summer/winter time shift
- manual mode
- current date setting
- random mode
- random mode setting
- impulse mode
- extenal input setting
- external input
- impulse mode setting
- winter time
- automatic,
- user
- summer time
- on/off
Button description
• in the main window - the automatic mode enter or relay state changeover, if the timer already in the automatic
mode;
• in the main window (3 seconds) - the random mode enter / exit;
• in the random mode - randomizing active/inactive manual toggle;
• the other windows - exit to a higher level without changes saving;
• in the main window - the manual mode enter or the relay state changeover, if the timer already in the manual mode;
• in the random mode - the relay state changeover and randomizing switch-OFF;
• the other windows - exit to a higher level without changes saving;
• in the main window - the main menu enter;
• the other windows - a submenu enter or setting acknowledgement;
• window/option toggle or set value increase/decrease;
Menu enter by pressing OK;
menu items scrolling by means of cursors
.
Function Description
PROGRAM SETTING
CURRENT
TIME
SETTING
CURRENT DATE SETTING
WINTER/SUMMER
TIME
SETTING
RANDOM MODE SETTING
EXTERNAL INPUT SETTING
IMPULSE MODE SETTING
TIME SETTING
WINTER / SUMMER TIME SETTING
OPERATING MODE CHANGE (AUTOMATIC, MANUAL, RANDOM)
- setting the current clock time; entry after pressing
OK;
HOUR- choose adequate hour with cursor
which you can
set in 1-24 or 1-12 (AM) and 1-12 (PM)format; con
fi
rm
with OK;
MINUTES - choose adequate parameter of minutes with cur-
sors
con
fi
rm with OK;
Con
fi
rmation of the parameter of minutes causes simultane-
ous nulli
fi
cation of the parameter of seconds and movement to
the window of time setting.
It is possible to exit every submenu window in any moment
without saving settings by pressing the button or .
- winter/summer time toggle mode selection:
-
automatic time changing on the last March Sunday, at 2:00
into summer time and on the last October Sunday, at 3:00 into
winter time,
- winter/summer timer toggle manual, by
user; option entering after pressing OK;
MODE SETTING - with
select
or
acknowl-
edge with OK; after selecting
, winter/summer time will
be toggled automatically; after selecting
mode you will
enter the next window;
With
select winter/summer, where is winter time, -
summer time; if the time icon is changed, the timer will correct
the current time appropriately; acknowledge by pressing OK;
After time mode selecting winter/summer time change window
will be open.
MANUAL OP MODE TOGGLE - if the main window is open
and the timer is in the automatic mode pressing key will
force the unit to toggle into the manual mode and the relay
state changeover;
Successive key pressing will force the relay state changeo-
ver without the op mode;
AUTOMATIC MODE TOGGLE - if the main window is open
and the timer is in the manual mode pressing key will force
the unit to toggle into the automatic mode and the relay state
changeover;
Successive key pressing will force the relay state change-
over without the op mode;
RANDOM MODE TOGGLE - in order to enter the random
mode it is necessary to press and hold key for
3 secs
;
Continuous light iindicates that the timer is not in the time
range where ON/OFF states randomizing is to be active, and
the pulsing light indicates that the unit is randomizing ON/
OFF states according to RANDOM MODE SETTING menu
settings; pressing key orces randomizing ON/OFF states
and the relay state changeover ( pulsing ), and RANDOM
MODE SETTING menu settings are still binding; successive
pressing key forces randomizing to be OFF;
Pressing key forces the relay changeover and randomiz-
ing switch-OFF, if it was active ( is lighting). The random
mode exit is possible by pressing and holding for
3 secs.
.
Randomizing activity/inactivity update is being operated either
in automatic or manual mode.