background image

PROGRAM VIEWING

PROGRAM SETTING

IMPULSE PROGRAM SETTING

PROGRAM CANCEL / RESTORE

 

 - the impulse generating mode switch ON / OFF and impulse duration time setting; the display shows the current 

mode state (

 - ON, 

 - OFF); enter edition with OK;

   With 

 cursors select the mode state 

 or 

; acknowledge selection with OK; if the option 

 selected, the main 

menu will be entered;

 If selected 

 set with 

 cursors impulse duration time in seconds; acknowledge with OK;

 After setting acknowledgement the impulse mode setting window is entered. In the impulse mode only   programs are 

available.

 

- de

fi

 ning ON-times and OFF-times for the given week’s days for the given programs running in automatic mode 

messages on busy ON and OFF programs quantities are being showed alternatively in the current window  , 

(e. g. 

); edition entering by pressing OK; the programs are numbered as pairs (  / 

). Max programs quantity is 

equal to 200   / 

 pairs;

 With 

 cursors select a program at (e.g. 

   ) for parameters editing and enter editing mode with OK;

 HOUR - with 

 cursors select an hour, acknowledge with OK;

 MINUTE - with 

 cursors select minutes, acknowledge with OK;

 WEEK’s DAY - with 

 cursors select the week’s day when the given program is to be active (there are 16 week division 

combinations available); acknowledge with OK - the program will be saved;

 The next stored program will be displayed (e.g. 

  

) - Press OK. to enter edition; in order to select the other pro-

gram use 

 cursors, to exit programming press   or  ;

 The last program is 

  

.

 PROGRAM VIEWING - viewing settings for the switching pro-

grams (  / 

) i.e. hours, minutes and the week’s days; enter 

viewing with OK;

   In order to scroll the programs press successively cursor 

; cursor   increases the program no.;   cursor decreases 

the program no.;

 The programs are numbered in the form of ON / OFF pairs

(  / 

) where every program may be treated independently; 

there are 400 programs (200 pairs   / 

).

It is possible to exit every submenu window in any moment 

without saving settings by pressing the button   or  .

 PROGRAM CANCEL / RESTORE - the option is used during program setting and viewing for program cancelling (inacti-

vation) and restoring; enter by pressing OK;

 With 

 select the program to be cancelled / restored;

 Press and hold OK for 3 seconds - if the program is active it will be cancelled (inactivated) and will not be checked during 

the timer operating in the automatic mode (however it will by saved in the storage and it will be possible to restore the 

program); horizontal lines will be displayed;

 If the program is cancelled, it will be restored by pressing OK and its edition will be possible  , pressing and holding OK 

for 3 seconds will cause the program restoring without time edition possibility  .

Week division combinations

 1 

 2 

 3 

 4 

 5 

 6 

 7 

 8 

 9 

 10 

 11 

 12 

 13 

 14 

 15 

 16 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXTERNAL INPUT SETTING

MAIN RESET

RANDOM MODE SETTING

 

 - setting the unit mode after the IN external input triggering; enter edition by 

pressing OK; with cursors 

 select an appropriate external input mode, where:

 

 - the external input function is OFF;

   

 - the manual mode with the relay continuous switch-OFF;

   

 - the manual mode with the relay continuous switch-ON;

   - the automatic mode, the relay is being switched ON / OFF according to the preset 

programs;

   - the random mode according to the RANDOM MODE SETTING menu settings;

 Acknowledge selection with OK; after acknowledgement the external input settings win-

dow will be entered.

It is possible to exit every submenu window in any moment without saving settings 

by pressing the button   or  .

 In order to cancel the clock system (time, date, activity of given functions etc.) you 

should hold buttons (  and  ) simultaneously in the main menu for 

3 sec

;

 All the display 

fi

 elds will light up;

 After a while,  the clock will automatically set date and time.

Attention: In order to restore factory settings, you should additionally hold button OK

 

 - setting the time range and days when the randomize function is to be ON and 

de

fi

 ning maximum relay ON-time and OFF-time in the random mode; enter with OK; 

select the appropriate window with 

 cursors, where:

   - de

fi

 ning the time and day of the random mode beginning (active randomizing);

 

 - de

fi

 ning the time and day of the random mode ending (inactive randomizing);

 

 - de

fi

 ning maximum relay ON-time in minutes - the time will be randomized for the 

range from 1 minute to 

 minutes;

 

 - de

fi

 ning maximum relay OFF-time in minutes - the time will be randomized for 

the range from 1 minute to 

 minutes; 

Window  : press OK to enter;   with 

 cursors set randomizing ON hour, acknowledge 

with OK;   with 

 set randomizing ON minute, acknowledge with OK;   with 

 cur-

sors set the days when randomizing is to be ON, acknowledge with OK; window   will 

be open.
Window  : press OK to enter;   with 

 cursors set randomizing OFF hour, acknowledge 

with OK;   with 

 set randomizing OFF minute, acknowledge with OK;   with 

 cur-

sors set the days when randomizing is to be OFF, acknowledge with OK; window   will 

be open. 
Window  : press OK to enter;   with 

 cursors set maximum ON- time (in minutes), 

acknowledge with OK; window   will be open.
Window  : press OK to enter;   with 

 cursors set maximum OFF-time (in minutes), 

acknowledge with OK; window   will be open.

It is possible to exit every submenu window in any moment without saving settings 

by pressing the button   or  .

5m

7m 3m

4m

8m 1m

2m

3m

3m

1m

2m

1m

4m

t

11    14

11    14

CONNECTION

MOUNTING

ADVANTAGES

Intelligent calendar

 - the programmer is 

fi

 tted with a built-in calendar

which 

fi

 ts leap years automatically, disables entering incorrect dates,

calculates a week’s day on the basis of the current date and 

fi

 ts the

summer / winter time change.

General purpose external input

 - the programmer is 

fi

 tted with an ex-

ternal input that enables the operating mode change without operating
a switchboard, e.g. by means of a remote push button.

Programmable random mode

 - it is possible to set beginning and

ending time, and the day of the random mode activity. Additionally, it
is possible to program maximum ON and OFF times in dependence
of user’s needs.

Additional impulse mode

 - it is possible to switch the timer into the

impulse mode which gives control units new capabilities.

DIMENSIONS

PRODUCT FAMILY

ZCM-11 Programmer belongs to ZCM 

family of products.

1. Disconnect power supply by the phase 

fuse, the circuit-breaker or the switch- 
disconnector combined to the proper 
circuit.

2. Check if there is no voltage on con-

nection cables by means of a special 
measure equipment.

3. Install the ZCM-11 on the TH 35 DIN 

rail in the switchboard.

4. Connect the cables with the terminals in 

accordance with the installing diagram.

5. Switch on the power supply from the 

mains.

WARRANTY CARD

Salesman stamp and signature, date of sale

There is 24 months guarantee on the product

1. ZMIE ZAMEL SP. J. assures 24 months guarantee for the product.
2. The manufacturer’s guarantee does not cover any of the following actions:

a) mechanical damage during transport, loading / unloading or under other circumstances,
b) damage caused by incorrect product mounting or misuse,
c) damage caused by unauthorised modi

fi

 cations made by the PURCHASER or any third parties to the product or any other devices 

needed for the product functioning, 

d)  damage caused by Act of God or any other incidents independent of the manufacturer.

3. The PURCHASER shall lay any claims in writing to the dealer or ZMIE ZAMEL SP. J.
4. ZMIE ZAMEL SP. J. is liable for processing any claim according to current Polish legislation.
5. ZMIE ZAMEL SP. J. shall process the claim at its own discretion: product repair, replacement  or money return. 
6. The manufacturer’s guarantee is valid in the Republic of Poland.
7. The PURCHASER’s  statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or 

otherwise are not affected by this warranty.

INNER DIAGRAM

RELAY CAPACITY

L(+)

L(+) / N(-)

N(-)

A2

A1

IN

μ

C

KLAW.

LCD

RTC

ZAS.

Programmer type:

11 - week (1 channel)
12 - week (2 channel)
21 - year
31 - astronomical

Device type

Power supply:

ZCM-xx - 

230 V AC

ZCM-xx/U -  24 ÷ 250 VAC
 

30 ÷ 300 V DC

Reviews: