Specifications
16-92
16.10.3
Cam Pattern Editing Execution Area
●
:
Available, -: Not available
Axis no.
Unit
memory
no. (Hex)
Name
Default
Description
R
W
-
UM 66F98
Cam pattern
reading result
H0
Stores the result of reading processing
(response code).
H0: Normal end
Other than H0: Abnormal end
-
-
UM 66F99
Cam pattern
rewriting result
H0
Stores the result of rewriting processing
(response code).
H0: Normal end
Other than H0: Abnormal end
-
(Note): In the case of abnormal end, the codes in the following table are stored.
Code
Name
Description
Object
Countermeasures
R
W
H FF01
Cam pattern number
setting error
Cam pattern no. The
setting value is out of the
range.
Check the set value of the cam
pattern number.
H FF02
Number of cam
pattern setting
sections setting error
The set number of cam
pattern setting sections is
out of the settable range.
-
Check the set number of setting
sections.
H FF03
Shift amount setting
error
The set shift amount is out
of the settable range.
-
Check the set value of the shift
amount.
H FF05
Start phase setting
error 1
The set start phase is out
of the settable range.
-
Check the set value of the start
phase in each section.
H FF06
Start phase setting
error 2
The set start phase is the
same as or smaller than
the start phase of the
previous section.
-
Check if the relation between
the start phases of each section
is (Start phase of section n-1) <
(Start phase of section n).
H FF07
Start phase setting
error 3
The set start phase of the
section 1 is not 0.
-
Always set the start phase of
the section 1 to 0.
H FF0A
Displacement setting
error
The set value of the
displacement is out of the
settable range.
-
Check the set value of the
phase in each section.
H FF0B
Cam curve number
setting error
The set cam curve
number is out of the
settable range.
-
Check the set value of the cam
curve number in each section.
H FF10
Cam pattern reading
not executable error 1
An axis in synchronous
operation exists.
-
Cancel the synchronous
operation and execute the
reading.
H FF11
Cam pattern reading
not executable error 2
An operating axis exists.
-
Execute the reading when no
operating axis exists.
H FF20
Cam pattern rewriting
not executable error 1
An axis in synchronous
operation exists.
-
Cancel the synchronous
operation and execute the
rewriting.
H FF21
Cam pattern rewriting
not executable error 2
An operating axis exists.
-
Execute the rewriting when no
operating axis exists.
H FF22
Cam pattern rewriting
not executable error 3
The reading request and
rewriting request turned
on simultaneously.
-
Check if the reading request
and rewriting request do not
turn on simultaneously. When
the reading request and writing
request turn on simultaneously,
the reading request takes
priority.
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......