16.5
Unit
Memories (Common Area)
16-47
16.5.12
Synchronous Control Monitor Area
●
:
Available, -: Not available
Axis no.
Unit
memory
no. (Hex)
Name
Default
Description
R
W
1
UM 02390
Synchronous
master axis
information
monitor
HFFFF
Stores the information on the master axis of
synchronous control.
Value
Master axis
Under
synchrono
us control
Synchrono
us control
canceled
H FFFF
H FFFF
No synchronous
setting
H 0000
H 8000
The target axis for
monitoring is the
master axis.
(For FP7 MC Unit,
the value for the
master axis does
not change even
when the
synchronous
control is
canceled.)
H 0001
H 8001
Axis 1
H 0002
H 8002
Axis 2
:
:
:
H 0010
H 8010
Axis 16
:
:
:
H 0020
H 8020
Axis 32
:
:
:
H 0040
H 8040
Axis 64
H 0041
H 8041
Virtual axis 1
:
:
:
H 0060
H 8060
Virtual axis 32
-
1
UM 02391
Synchronous
output
function
selected state
monitor
H0
Stores the information on the master axis of
synchronous control.
bit.
Name
Value
0
Electronic gear
operation settings
0: Not use
1: Use
1
Clutch operation
setting
2
Electronic cam
operation setting
3
Advance angle
correction
operation setting
15-4
-
-
-
1
UM 02392
-UM 02395
Reserved for
system
-
-
-
-
(2-64
Virtual 1-32)
UM 02396
-UM 025CF
As well as the area for axis 1, 6-word area is allocated to each axis in the
following configuration.
Synchronous master axis information monitor area: 1 word
Synchronous output function selected state monitor area: 1 word
Reserved area for the system: 4 words
-
-
UM 025D0
-UM 0260F
Reserved for
system
-
-
-
-
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......