16.4
Unit
Memories (Input and Output Control Areas)
16-27
16.4.4 List of Output Control Area Functions
●
:
Available, -: Not available
Axis no.
Unit
memory
no. (Hex)
Name
Default
Description
R
W
-
UM 00180
-UM 00185
Reserved for
system
-
-
-
-
1-16
UM 00186
Servo ON
request
H0
Requests the servo lock for the corresponding
AMP.
This request signal is enabled when the bits
corresponding to each axis number turn on.
(The operation is the edge type.)
17-32
UM 00187
33-48
UM 00188
49-64
UM 00189
-
UM 0018A
-UM 0018B
Reserved for
system
-
-
-
-
1-16
UM 0018C
Servo OFF
request
H0
Requests the servo free for the corresponding
AMP.
This request signal is enabled when the bits
corresponding to each axis number turn on.
(The operation is the edge type.)
17-32
UM 0018D
33-48
UM 0018E
49-64
UM 0018F
-
UM 00190
-UM 00191
Reserved for
system
-
-
-
-
1-16
UM 00192
Positioning
start request
H0
Requests the positioning control start for the
corresponding axis.
The starting table is specified in the area for
specifying the position control starting table
number in the unit memory.
This request signal is enabled when the bits
corresponding to each axis number turn on.
(The operation is the edge type.)
17-32
UM 00193
33-48
UM 00194
49-64
UM 00195
Virtual 1-16
UM 00196
Virtual 17-32
UM 00197
1-16
UM 00198
Home return
start request
H0
Requests the home return operation start for
the corresponding axis.
This request signal is enabled when the bits
corresponding to each axis number turn on.
(The operation is the edge type.)
17-32
UM 00199
33-48
UM 0019A
49-64
UM 0019B
Virtual 1-16
UM 0019C
Virtual 17-32
UM 0019D
(Note 1): Request flags for 16 axes are allocated to each area (1 word).
bit no. 15
0
8 7
9
1
8
16
● ● ● ● ● ●
● ● ● ● ● ●
Axis no.
25
17
24
32
● ● ● ● ● ●
● ● ● ● ● ●
41
33
40
48
● ● ● ● ● ●
● ● ● ● ● ●
57
49
56
64
● ● ● ● ● ●
● ● ● ● ● ●
(Note 2): The servo cannot be free automatically even in the program mode. To make the servo free, turn on the
Servo OFF request.
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......