Specifications
16-80
16.8.5 Electronic Cam Setting Area
●
:
Available, -: Not available
Axis no.
Unit
memory
no. (Hex)
Name
Default Description
R
W
1
UM 63F90
-UM 63F91
Cam control
synchronous
master axis
cycle
U1
Set the cam control synchronous master cycle.
U1 to U2147483647
1
UM 63F92
Reserved for
system
-
-
-
-
1
UM 63F93
Cam pattern
number
U1
Set the registered cam pattern number to be used.
1 to 256
1
UM 63F94
-UM 63F95
Cam stroke
amount
U1
Displacement amount upper limit setting for cam
control
U1 to U2147483647
1
UM 63F96
-UM 63F97
Advance
angle
correction
reference
amount
K0
Set the correction reference amount for calculating
the advance angle correction amount when using
the advance angle correction function.
Range: -2,147,483,648 to 2,147,483,647
The ranges vary depending on the unit settings as
below.
pulse: -2,147,483,648 to 2,147,483,647 pulses
μm (0.1 μm):
-
214,748,364.8 to 214,748,364.7 μm
μm (1 μm):
-
2,147,483,648 to 2,147,483,647 μm
inch (0.00001 inch): -21,474.83648 to 21,474.83647
inches
inch (0.0001 inch): -214,748.3648 to 214,748.3647
inches
degree (0.1 degree): -214,748,364.8 to
214,748,364.7 degrees
degree (1 degree): -2,147,483,648 to 2,147,483,647
degrees
Any other settings will be errors.
1
UM 63F98
-UM 63F99
Advance
angle
correction
reference
speed
U100
Set the reference speed for calculating the advance
angle correction amount when using the advance
angle correction function.
Range: 1 to 2,147,483,647
Any other settings will be errors.
The ranges vary depending on the unit settings as
below.
pulse: 1 to 2,147,483,647 pps
μm: 1 to 2,147,483,647 μm/s
inch: 0.001 to 2,147,483.647 inch/s
degree: 0.001 to 2,147,483.647 rev/s
(Note): The above table shows the unit memory numbers of axis number 1. For details of the whole configuration,
refer to "16.8.1 Configuration of Synchronous Control Setting Area".
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......