Automatic
Operation (Synchronous Control)
9-52
Precautions when using phase shift amount
•
Specify the values when the phase shift amount is 0(%) for the parameter values of cam
pattern (starting phase, displacement and cam curve).
•
The starting phase of the section number 1 is 0(%). When any values other than 0(%), an
error will occur. For starting phases after the section number 2, specify arbitrary starting
phases. When reading and writing settings, the closest phase will be automatically
calculated within the unit from the resolution.
•
After setting the cam pattern when the phase shift amount is 0(%), set a phase shift amount.
When reading and writing settings, the closest phase amount will be automatically calculated
within the unit from the resolution.
For rewriting the cam pattern set on CMI to a user program, perform the following procedure.
(1) Record the phase shift amount specified on CMI.
(2) The phase shift amount has been added to the starting phase displayed on CMI. Set the
phase shift amount to 0(%) to confirm the parameter values of cam pattern (starting phase,
displacement, cam curve).
(3) Use the parameter values acquired in (2) on user programs. As for the starting phase, use
values to two decimal places.
(4) Set the phase shift amount recorded in (1). As well as the starting phase, use values to
two decimal places.
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......