Specifications
16-70
16.7.4.1 Control Area for Buffer Control
This area is used for reading or writing positioning data by user programs.
●
:
Available, -: Not available
Buffer no.
Unit
memory
no. (Hex)
Name
Default Description
R
W
1
UM 06240
Request
flag control
H0
Write data to this area for sending/receiving data of
buffers for positioning data. After the completion of
the execution, it is rewritten to H0 by FP7 MC Unit.
H0000: No request
H0001: Request
Any other settings will be errors.
1
UM 06241
Request
code control
H0
Set the request code of data control of buffer for
positioning data.
H0080: Read request
H0081: Write request
Any other settings will be errors.
1
UM 06242
Response
code control
H0
Stores the response code for the request of the
buffer for positioning data.
H0000: Complete
H0001: In progress
HFF00: Setting value error
-
1
UM 06243
Axis
number
control
U1
Specify the axis number of positioning data to be
transferred.
Range
Corresponding axis no.
1-64
Corresponds to the existing axes 1 to 64.
65-96
Corresponds to the virtual axes 1 to 32.
Any other settings will be errors.
1
UM 06244
Starting
table
number
U1
Specify the starting table number of positioning data
to be transferred.
Range: 1 to 1000
Any other settings will be errors.
1
UM 06245
Table size
U1
Specify the table size of positioning data to be
transferred.
Range: 1 to 500
Any other settings will be errors.
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......