16.7
Unit
Memories (Each Axis Setting Area)
16-73
●
:
Available, -: Not available
Offset
address
Name
Default Description
R
W
006H
-007H
Positioning
target speed
(Interpolation
speed)
U1000
For a single axis operation, it is the target speed of the
corresponding axis. For an interpolation operation, it is the target
speed of the interpolation. In the interpolation operation, the
setting for the axis with the smallest number in an axis group is
effective.
Range: 1 to 2,147,483,647
Any other settings will be errors.
The ranges vary depending on the unit settings as below.
pulse: 1 to 2,147,483,647 pps
μm: 1 to 2,147,483,647 μm/s
inch: 0.001 to 2,147,483.647 inch/s
degree: 0.001 to 2,147,483.647 rev/s
008H
-009H
Positioning
movement
amount
K0
Set the position command value for the positioning operation. It is
the movement amount in the case of increment, and coordinates
in the case of absolute depending on the control code setting.
Range: -2,147,483,648 to +2,147,483,647
Any other settings will be errors.
The ranges vary depending on the unit settings as below.
pulse: -2,147,483,648 to 2,147,483,647 pulse
μm (0.1μm):
-
214,748,364.8 to 214,748,364.7 μm
μm (1μm):
-
2,147,483,648 to 2,147,483,647 μm
inch (0.00001 inch): -21,474.83648 to 21,474.83647 inches
inch (0.0001 inch): -214,748.3648 to 214,748.3647 inches
degree (0.1 degree): -214,748,364.8 to 214,748,364.7 degrees
degree (1 degree): -2,147,483,648 to 2,147,483,647 degrees
00AH
-00BH
Auxiliary
point
K0
Set the auxiliary point (coordinate of center or pass point) in the
case of circular interpolation or spiral interpolation control.
Range: -2,147,483,648 to +2,147,483,647
Any other settings will be errors.
The ranges vary depending on the unit settings as below.
pulse: -2,147,483,648 to 2,147,483,647 pulse
μm (0.1μm):
-
214,748,364.8 to 214,748,364.7 μm
μm (1μm):
-
2,147,483,648 to 2,147,483,647 μm
inch (0.00001 inch): -21,474.83648 to 21,474.83647 inches
inch (0.0001 inch): -214,748.3648 to 214,748.3647 inches
degree (0.1 degree): -214,748,364.8 to 214,748,364.7 degrees
degree (1 degree): -2,147,483,648 to 2,147,483,647 degrees
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......