12.2
Settings Related to Stop Function
12-7
12.2 Settings Related to Stop Function
12.2.1 MC Common Settings
•
An operation when an error occurs is specified in the "MC common settings" dialog box.
•
Specify the items in "Parameter" > "MC common settings" of CMI.
Parameter name
Default
Description
Operation when an error
occurs
All axes stop
Set the operation performed when an error occurs in axes
(nodes) connected to the network.
All axes stop
All axes operations stop. (Note 1)
Stops normal axes in the deceleration time
activated when an error occurs.
Normal axis
operation
continuance
The operation of the axis an error occurred
stops. The operations of normal axes
continue.
Deceleration stop
operation
Deceleration
stop
The operation when the deceleration stop request of unit
memories (output control area) turns on is set.
Deceleration stop / Pause
RUN->PROG. operation
Deceleration
stop
Set the operation when the operation mode of CPU unit changes
from RUN to PROG.
Operation
continuance
The operation of each axis continues.
Deceleration
stop
Each axis decelerates and stops in a
specified deceleration stop time in the current
control mode.
Immediate stop
Each axis decelerates and stops in a
specified emergency stop deceleration time.
Error alarm to CPU unit
Yes
Set the method of notifying errors to the CPU unit. The operation
mode of the CPU unit when an error occurs is set from "CPU
configuration" - "Unit error" in FPWIN GR7.
Yes
Announces errors to the CPU unit.
No
Not announce errors to the CPU unit.
(Note 1): When setting "All axes stop", normal axes will stop once when an error occurs in the JOG/inching operation,
however, if the JOG operation request is on after they stopped, the JOG/inching operation will start again.
Create a user program to use the error annunciation flag as an interlock signal to stop the JOG/inching
operation.
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......