8.2
Interpolation Control
8-23
Operation diagram
100
100
f [pps]
10000
t [ms]
20000
20000
5000
0
30000
10000
Composite speed
Positioning start request of 1st axis
Current value of 1st axis
Current value of 2nd axis
Current value of 3rd axis
Operation done flag of 1st axis
Operation done flag of 2nd axis
Operation done flag of 3rd axis
BUSY flag of 1st axis
BUSY flag of 2nd axis
BUSY flag of 3rd axis
Operation of input control/output control signals
•
When a positioning start request (corresponding bit allocated to UM00192 to UM00197)
turns on by a user program, the positioning control will start. The positioning start request will
be enabled at the edge where it turns on. In the interpolation control, turn on the positioning
start request of the smallest axis number in the same interpolation group.
•
A busy flag (corresponding bit allocated to UM00090 to UM00095), which indicates that a
motor is running, will turn on when the positioning control starts, and it will turn off when the
operation completes.
•
An operation done flag (corresponding bit allocated to UM00096 to UM0009B), which
indicates the completion of operation, will turn on when the current operation is completed,
and it will be held until the next positioning control, JOG operation, or home return starts.
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......