5.2
Axis Parameter Settings
5-9
Monitor setting
Parameter name
Default
Description
Movement check operation
UM 0324A
2: None
Select the operation when exceeding the movement amount
automatic check threshold.
0: Error, 1: Warning, 2: None
Movement check value (pulse)
UM 03258-UM 03259
10000
Set the threshold for the movement amount automatic check
operation. (Note)
Extend
monitor value
Range
1 word
0 to 65535 pulses
2 words
0 to 2147483647 pulses
Completion width check time
(ms)
UM 03257
0
Specify the width of the completion of command operation.
When "0" is set, the completion width is not checked.
Range: 0 to 10,000 ms
Completion width (pulse)
UM 0325A-UM 0325B
10
Turns on the completion flag when the AMP current value
[feedback value] becomes within this completion width after
the movement of a set amount during the positioning control,
JOG operation.
Range: 1 to 2,147,483,647
Any other settings will be errors.
Monitor error
- Torque judgement
UM 0325C bit1-0
N: Disabled
Select the operation of FP7 MC Unit when the torque value of
the amplifier is monitored and exceeds the judgement value.
N: Disabled, E: Enabled (Error), W: Enabled (Warning)
Monitor error-
Torque judgement value (%)
UM 0325D
5000
Set the torque judgement value.
Range: 0 to 5000 (0.0 % to 500.0 %)
Monitor error
- Actual speed judgement
UM 0325C bit3-2
N: Disabled
Select the operation of FP7 MC Unit when the actual speed of
the amplifier is monitored and exceeds the judgement value.
N: Disabled, E: Enabled (Error), W: Enabled (Warning)
Monitor error -
Actual speed judgement value
unit
UM 0325C bit4
0: 0.1 rpm
When "2 words" is set for "Extend monitor value", set the unit
for the monitor error actual speed judgement. (Note)
0: 0.1 rpm
1: Command unit/s
Monitor error
- Actual speed judgement value
UM 0325E-UM 0325F
5000
Set the actual speed judgement value. (Note)
Extend
monitor value
Monitor error
unit
Range
1 word
1 rpm
0 to 5000 rpm
2 words
0.1 rpm
0 to 6500.0 rpm
Command
unit/s
2147483647 command
unit/s
(Note): The values set in these parameters are stored in the unit memory numbers described below the parameter
names.
REFERENCE
•
For details of each function of software limit, auxiliary output and monitor
setting, refer to "13 Supplementary Functions".
•
For details of the "Extend monitor value" setting, refer to "5.1.2 FP7 MC Unit
Common Settings Parameters".
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......