Automatic
Operation (Synchronous Control)
9-46
The cam pattern reading results are as follows.
Axis
no.
Unit
memory
no. (Hex)
Name Default Unit
Setting range and description
-
UM 66F98
Cam
pattern
reading
result
H0
-
- The result of reading processing (response code) is stored.
Code
Name
Description
Countermeasures
H0
Normal end
-
-
HFF01
Cam pattern
number
setting error
The cam
pattern
setting value
is out of the
settable
range.
Check the set value
of the cam pattern
number.
HFF10
Cam pattern
reading not
executable
error 1
An axis in
synchronous
operation
exists.
Cancel the
synchronous
operation and
execute the reading.
HFF11
Cam pattern
reading not
executable
error 2
An operating
axis exists.
Execute the reading
when no operating
axis exists.
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......