Troubleshooting
15-22
15.3.6 Synchronous Parameter Setting Errors (From 00F0 5000H)
Synchronous parameter: Common errors
●
:
Recoverable, -: Unrecoverable
Error
code
Error name
Description
Object Recovered
Countermeasures
5000H
Synchronous master
setting value error
The setting for the synchronous
master axis is incorrect.
- Setting error (Value is
incorrect.)
- Own axis setting
Each
axis
Check the set value.
If the error occurs repeatedly
with the correct set values,
please contact us.
5002H
Synchronous setting
disable error
The synchronous setting
request was made in the
following axis setting.
- Its own axis (slave axis) is set
as the master of another axis.
- The master axis is set as the
slave axis of another axis.
- Its own axis (slave axis)
belongs to the interpolation
group.
Each
axis
5006H
Synchronous slave
single deceleration
stop deceleration
time
The setting for the synchronous
slave single deceleration stop
time is incorrect.
Each
axis
(Note): To simplify the displays, only the lower four digits (Hex) of each error code are displayed in the above table.
Synchronous parameter: Electronic gear related errors
●
:
Recoverable, -: Unrecoverable
Error
code
Error name
Description
Object Recovered
Countermeasures
5100H
Electronic gear -
Gear ratio
numerator setting
error
The setting for the gear ratio
numerator of the electronic gear
is incorrect.
Each
axis
Check the set value.
If the error occurs repeatedly
with the correct set values,
please contact us.
5101H
Electronic gear -
Gear ratio
denominator setting
error
The setting for the gear ratio
denominator of the electronic
gear is incorrect.
Each
axis
5102H
Electronic gear-
Gear ratio change
time setting error
The setting for the gear ratio
change time of the electronic
gear is incorrect.
Each
axis
(Note): To simplify the displays, only the lower four digits (Hex) of each error code are displayed in the above table.
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......