8.4
Target Speed Change Function
8-33
8.4.3 Setting Procedures and Operations (Ratio Specification Method)
Setting procedures and operations of ratio specification method (Override)
When setting the ratio specification, the command speed is immediately reflected in the
specified ratio once the "Ratio specification" in the unit memory is changed.
f
t
50,000pps
100,000pps
200,000pps
Operation speed rate
100(%)
200(%)
50(%)
100(%)
(Note 1): The acceleration time to the change speed and the deceleration time from the change speed follow the
setting values of the active table.
(Note 2): The movement amount does not change when the speed change is performed.
Setting parameters of ratio specification method
The following parameters are used in the target speed change function of the ratio
specification method.
Positioning operation change setting area
Axis no.
Unit
memory
no. (Hex)
Name
Default
Description
Axis 1
UM 00380
Operation
speed rate
U100
All operations relating to axes (positioning, JOG
operation, home return) can be performed at the
specified rate.
Range: 0 to 500 (%) (For single axis control)
0 to 200 (%) (For interpolation control)
Axis 2
UM 00381
:
:
Virtual
axis 1
UM 003C0
:
:
Virtual
axis 32
UM 003DF
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......