Items Requiring Particular Attention
iii
Items Requiring Particular Attention
When using FP7 MC Unit in combination with Servo Amplifier A6B/A5B, please note the
followings.
Wiring of Power Supply
To avoid influence of noise, keep the power supply systems of servo amplifier and PLC
separate.
Connection of Over Limit Input
•
In the system using FP7 MC Unit and Servo Amplifier A6B/A5B, limit switches are connected
to the general-purpose inputs (SI-MON3 and SI-MON4) of Servo Amplifier A6B/A5B to
enable the control by a high-order PLC (FP7 MC Unit).
•
The POT/NOT input of the servo amplifier A6B/A5B cannot be used as the limit input of a
high-order PLC (FP7 MC Unit).
•
For using the general-purpose inputs of the servo amplifier A6B/A5B (SI-MON3 and SI-
MON4) as the limit input of a high-order PLC (FP7 MC Unit), parameters of the servo
amplifier A6B/A5B and FP7 MC need to be changed. For details, refer to "4.5 Connection of
Limit and Near Home Switches".
Operation when home return operation is performed
For the home return methods which are based on the home position (Z phase) (i.e. DOG
method 1, DOG method 3, Limit method 1, Z phase method and Stop-on-contact method 2),
the home return operation after shifting to the creep speed is controlled by the servo amplifier
A6B/A5B. During this operation, the high-order PLC (FP7 MC Unit) cannot control the
operation. Please design and evaluate the system to avoid any danger even after shifting to
the creep speed.
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......