15.4
Warning Code Table
15-31
●
:
Recoverable, -: Unrecoverable
Warning
code
Warning
name
Description
Object Recovered
Countermeasures
0111H
Cam pattern
table over-
writing
warning
The operation for the cam pattern
table rewriting request ended
abnormally as an incorrect value
was set or the execution condition
was not satisfied.
All
axes
- Confirm the setting values of the
parameters required for rewriting
cam patterns.
- Confirm if any axes are in
synchronous operation.
If any, cancel the synchronous
operation and rewrite the cam
pattern tables.
* The details about the cause of
the occurrence of this warning are
stored in the “cam pattern
rewriting result” area of unit
memories.
0120H
Trigger
setting
warning
The trigger condition setting error
occurred.
All
axes
Check that the trigger conditions
are set correctly.
0121H
Tool logging
function
enable
warning
When UM02613 is on (logging
enabled), it is detected that YB is
on.
All
axes
After setting UM02613 to off, turn
on the YB (logging enabled).
0300H
Control area
for buffer
control value
warning
The following parameters of the
control area for buffer control is
out of the range.
- Request flag control
- Request code control
- Response code control
- Axis number control
- Starting table number
- Table size
- Extended positioning table
usage setting
- Extended positioning table
usage setting corresponding axis
no.
All
axes
/Each
axis
- Confirm the setting values of the
parameters for control area for
buffer control.
0304H
Recalculation
error warning
An error occurred when
recalculation was performed.
Each
axis
Even when the error occurred,
recalculation process in which no
error occurs is executed.
Check the settings and execute
the recalculation process again.
(Note): To simplify the displays, only the lower four digits (Hex) of each warning code are displayed in the above table.
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......