6.3
Checking While the Power is ON
6-7
6.3.4 Checking the Operation of Near Home Input
Procedure 1
Check if the near home input is loaded as an input signal on the PLC properly by operating
the input forcibly.
Procedure 2
Start the home return by the tool operation function of CMI or inputting the home return
program, and check if the operation transits to the deceleration operation by the near home
input.
Points to check
The logic of near home input depends on the settings of Servo Amplifier and FP7 MC Unit.
Procedure 3
Check if the home stop position shifts by repeating the JOG and home return operations.
Procedure 4
If the home stopping position is shifted, change the position of near home input or reduce the
home return speed.
6.3.5 Checking Rotating and Moving Directions and Moving Distance
Procedure 1
Execute the JOG operation to confirm the rotating direction and moving direction of the motor.
Use the tool operation function of CMI and perform the JOG operation.
Points to check
The rotating direction is determined according to the installation of the ball screw or the
"CW/CCW direction setting" of the axis parameter.
Procedure 2
Check if the moving distance is that as designed by performing the JOG operation or
positioning operation.
Points to check
The moving distance is determined according to the pitch of the ball screw, deceleration gear
ratio or setting movement amount of the positioning data.
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......